Installation
Component Cooking Surfaces
9
Step
Connect Halogen/Radiant, updraft grill, downdraft grill and
electn”cal downdraft vent component:
3-Conductor Branch Circu]t
Branch Circuit Cooktop

Electrical

Powe?-

requirements

.3-Conductor
Red Red
+120V AC White or
Gray White
Neutral
Bare or
Green
Black Black
-120VAC
Branch Circuit: \J
Lhagram56.1
Connect red lead to branch circuit red lead.
Connect black lead to branch circuit black lead.
oConnect bare or green conductor and white lead* of
cooktop to branch circuit neutral lead, which iswhite
or gray.
4-Conductor Branch Clrcuh
Branch C[rcuit Cooktop
Red Red
+120V AC
White or
INeutral Gray White
-120VAC :Black Black
4Conductor Bare or Bare or
GND Green Green
Branch Circuit:
1
Llagram 56.2
Connect red lead to branch circuit red lead.
-Connect black lead to branch circuit black lead.
.Break connection between cooktop white lead to bare The frames of these appliances are grounded to neutral.
or green conductor.
.Connect cooktop white lead* to branch circuit neutral *Updraft grill has no white neutral wire. Connect only
lead, which iswhite or gray. black, red and bare wires as shown. Downdraft vent
Ground unit by connecting bare conductor of cooktop has no red wire. Attach white, green and black wires
to branch circuit bare or green lead (ground lead). asshown.
,Model #
ZGW124
ZGW125
ZEW145T
ZEW145T
ZEW154
ZEW155
ZEW164
ZEWI 65
ZEW175
Voltage
120
120
208
240
208
240
208
240
120
Frequency
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
AMPS
1.0
1.0
11.0
12.7
8.4
7.3
15.3
13.5
1.8
Kw