Figure 69. Pulleys properly aligned. V-belts are

parallel and coplaner.

If the pulleys are aligned, then no adjust- ments are necessary.

If the pulleys are NOT aligned, perform Steps 3 & 4.

3.Remove the V-belts (see Page 34), loosen the set screws on the end of the cutterhead pulley, and align the cutterhead pulley with the motor pulley.

4.Tighten the set screws, replace the V-belts, and repeat Step 2.

5.Reinstall the V-belt cover, fence bracket and fence assembly.

Setting Fence Stops

The fence stops simplify the task of adjusting the fence to 45˚ and 90˚.

Tools Needed

Qty

45° Square

1

90° Square

1

Sliding Bevel

1

Wrench 10mm

1

To set the 90˚ fence stop:

 

1.Loosen the lock nut on the 90° fence stop bolt shown in Figure 70, and loosen the fence tilt lock.

2.Place a 90° square against the table and fence, and adust the stop bolt, so the fence is set exactly at 90°.

Lock Nut

 

90˚Stop Bolt

 

 

 

Figure 70. Adjusting fence to 90˚.

3.

Tighten the lock nut.

4.

Adjust the indicator (if necessary) to 0° to

 

calibrate the fence tilt scale.

G0633/G0634 Jointer/Planer Combo Machine