D. Vent Diagrams

WARNING

Fire Risk. Explosion Risk.

Do NOT pack insulation or other combustibles between ceiling firestops.

ALWAYS maintain specified clearances around venting and firestop systems.

Install wall shield and ceiling firestops as specified.

Failure to keep insulation or other material away from vent pipe may cause fire.

1. Top Vent - Horizontal Termination

One Elbow

V1

H1

Figure 5.3

 

V1 Minimum

H1 Maximum

Cerona-36 ONLY

1/2 ft

152 mm

2 ft

 

610 mm

 

1 ft

305 mm

2 ft

 

610 mm

 

2 ft

610 mm

5 ft

 

1.5 m

 

3 ft

914 mm

8 ft

 

2.4 m

 

4 ft

 

1.2 m

11 ft

 

3.4 m

 

5 ft

 

1.5 m

14 ft

 

4.3 m

 

6 ft

 

1.8 m

17 ft

 

5.2 m

 

7 ft

 

2.1 m

20 ft

 

6.1 m

 

8 ft

 

2.4 m

23 ft

 

7.0 m

 

V1 = 40 ft. (12.2 m) Maximum

 

H1

= 23 ft. (7.0 m) Maximum

 

V1 + H1 = 63 ft. (19.2 m) Maximum

Note: Must have

Minimal Vertical Vent

a minimum verti-

Model

 

ft.

mm

cal vent before

 

Cerona-36

1/2

152

attaching a 90º

elbow to the unit.

Cerona-42

1

305

See chart.

 

 

 

 

 

Two Elbows

H2

 

V1 Minimum

H1 Maximum

Cerona-36 ONLY

1/2 ft

152 mm

2 ft

610 mm

 

1 ft

305 mm

2 ft

610 mm

 

2 ft

610 mm

5 ft

1.5 m

 

3 ft

914 mm

8 ft

2.4 m

 

4 ft

1.2 m

11 ft

3.4 m

 

5 ft

1.5 m

14 ft

4.3 m

 

6 ft

1.8 m

17 ft

5.2 m

V1

7 ft

2.1 m

20 ft

6.1 m

8 ft

2.4 m

23 ft

7.0 m

H1

V1 + H1

+ H2= 63 ft. (19.2 m) Maximum

 

 

H1 + H2 = 23 ft. (7.0 m) Maximum

INSTALLED

Note: Must have

Minimal Vertical Vent

HORIZONTALLY

 

a minimum verti-

Model

ft.

mm

 

cal vent before

 

Cerona-36

1/2

152

 

attaching a 90º

 

elbow to the unit.

Cerona-42

1

305

 

See chart.

 

 

 

Figure 5.4

16

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. H • 11/08

Page 16
Image 16