B. Facing Material

WARNING

Fire Risk.

Do NOT obstruct air inlet or outlet grilles. Do NOT modify grilles.

• Modifying or covering grilles could cause temperature rise and fire hazard.

Finishing materials must not interfere with:

Air flow through grilles or louvers.

Operation of louvers or doors.

Access for service.

WARNING

Fire Risk.

Finish all edges and fronts to clearances and specifications listed in manual.

Black metal appliance front may be covered with noncombustible material only.

Do NOT overlap combustible materials onto appliance front.

Install combustible materials only up to specified clearances on top, front and side.

Seal joints between the finished wall and appliance top and sides using only a 300º F minimum sealant.

NON-COMBUSTIBLE

FACING MATERIAL

B

1in.

(25 mm)

A

 

 

A

B

Cerona-36

in.

43-5/8

50-3/16

mm

1108

1275

 

Cerona-42

in.

50-5/8

54-3/8

mm

1286

1381

 

Figure 11.3 Non-combustible Facing Material

COMBUSTIBLE

SHEATHING

CLEARANCE

 

TO CEILING

CEILING

 

 

B MINIMUM

A

NON-COMBUSTIBLE

FACING MATERIAL

IN SHADED AREAS

FIREPLACE

ARCH OPENING

1 in.

(25)

C

BOTTOM OF FIREPLACE

TO BOTTOM OF

NON-COMBUSTIBLE

FACING MATERIAL

 

 

A

B

C

Cerona-36

in.

49

16-3/4

43-5/8

mm

1245

425

1108

Cerona-42

in.

45-1/4

16-3/4

50-5/8

mm

1149

425

1286

Figure 11.4

Note: If using the Apollo Mantel System, the appliance must be raised 1-1/4 in. from floor.

WARNING

Risk of Fire

Non-combustible clearances MUST be maintained.

Sheetrock, wood or other combustibles must

NOT be used as sheathing or facing in the non-combustible zone.

• See Section 11 for proper clearances.

• See Section 1 for combustible/non- combustible definitions.

36

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. H • 11/08

Page 36
Image 36