6 Vent Clearances and Framing

A. Pipe Clearances to Combustibles

WARNING

Fire Risk. Explosion Risk.

Maintain vent clearance to combustibles as specified.

Do not pack air space with insulation or other materials.

Failure to keep insulation or other materials away from vent pipe may cause fire.

 

3 in. TOP

 

CLEARANCE

 

1 in. CLEARANCE

 

AROUND VERTICAL

 

SECTIONS

 

1 in. SIDE AND

 

BOTTOM CLEARANCE

Figure 6.1

Pipe Clearances

Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm).

The heat shield is designed to be used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102

mm)the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B will be required.

B. Wall Penetration Framing

Combustible Wall Penetration

Frame a hole in a combustible wall for an interior wall shield firestop, (Figure 6.3) whenever a wall is penetrated. Use same size framing materials as those used in the wall construction. The wall shield firestop maintains minimum clearances and prevents cold air infiltration.

Non-Combustible Wall Penetration

If the hole being penetrated is surrounded by noncombus- tible materials such as concrete, a hole with diameter one inch greater than the pipe is acceptable.

Whenever a non-combustible wall is penetrated, the wall shield firestop is only required on one side and no heat shield is necessary.

If your local inspector requires the wall shield firestop on both sides, then both wall shield firestops must have a heat shield attached to them.

Shows center of 10 inch x 12 inch vent framing holes for top and rear venting. The center of the hole is one (1) inch (25.4 mm) above the center of the horizontal vent pipe.

B

HEAT

SHIELD

WALL

SHIELD

FIRESTOP

WALL

3 in. TOP

CLEARANCE

HEAT

SHIELD

1 in. CLEARANCE BOTTOM & SIDES

A

 

 

A

B

Cerona-36

in.

61-1/2

60-1/2

mm

1562

1537

 

Cerona-42

in.

72

71

mm

1829

1803

 

Figure 6.2 Horizontal venting clearances to combustible materials

Figure 6.3 Exterior Wall Hole

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. H • 11/08

19

Page 19
Image 19
Hearth and Home Technologies CERONA-42 owner manual Vent Clearances and Framing, Pipe Clearances to Combustibles