1. Top Vent - Horizontal Termination

- (continued)

 

 

 

 

 

Three Elbows

V1 Minimum

H1 Maximum

 

Cerona-36 ONLY 1/2 ft

152 mm

3 ft

 

914 mm

 

1 ft

305 mm

4 ft

 

1.2 m

 

2 ft

610 mm

7 ft

 

2.1 m

 

3 ft

914 mm

10 ft

 

3.0 m

H2

4 ft

1.2 m

13

 

4.0 m

5 ft

1.5 m

16

 

4.9 m

V2

 

6 ft

1.8 m

17

 

5.2 m

 

 

 

7 ft

2.1 m

22

 

6.7 m

 

H1

+ H2

= 22 ft. (6.7 m) Max.

 

V1+ V2 + H1 + H2 = 62 ft. (18.9 m) Max.

H1

V1

 

 

 

 

 

 

 

 

 

 

 

 

Note: Must have

Minimal Vertical Vent

 

a minimum verti-

Model

 

ft.

mm

 

cal vent before

 

 

Cerona-36

1/2

152

 

attaching a 90º

 

elbow to the unit.

Cerona-42

1

305

 

See chart.

 

 

 

 

 

Figure 5.5

2.Top Vent - Vertical Termination Straight up Vertical Venting

CAP

V1 = 50 ft. Max. (15.2 m)

Note: On vertical venting configurations install the flue restrictor found in the appliance manual bag. Follow flue restrictor instructions in Section 7D.

V1

Figure 5.6

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. H • 11/08

17

Page 17
Image 17
Hearth and Home Technologies CERONA-42 owner manual Top Vent Horizontal Termination Three Elbows, V1 = 50 ft. Max .2 m