Hearth and Home Technologies CERONA-42 owner manual Installing Flue Restrictors

Models: CERONA-42

1 65
Download 65 pages 15.61 Kb
Page 23
Image 23

Attach the left and right side pieces to the framing members. (See Figure 7.3).

NON-COMBUSTIBLE

FACING MATERIAL

B

1in.

(25 mm)

A

 

 

A

B

Cerona-36

in.

43-5/8

50-3/16

mm

1108

1275

 

Cerona-42

in.

50-5/8

54-3/8

mm

1286

1381

 

Figure 7.4 Complete Installation of Non-combustible Facing Material

Use a wet or dry towel or soft brush to remove dust or dirt from facing material.

Apply a non-combustible adhesive to attach tile, stone or other non-combustible finishing materials per manufacturer’s instructions.

D. Installing Flue Restrictors

Locate the flue restrictor and two screws inside the manual bag. Use the following table to determine which restrictors to use for the vent run.

Vent Run Vertical

15 ft. - 50 ft.

Cerona-36

1-1/4

Cerona-42

1-1/4

Mount the flue restrictor to the flapper door using two screws (see Figure 7.5).

EXHAUST

 

FLUE

COLLAR

 

 

RESTRICTOR

 

 

 

FIREBOX

 

 

TOP OF

 

 

FLAPPER

FIREPLACE

EXHAUST

 

DOOR

 

PORT

 

 

 

 

EXHAUST

FLUE

 

 

COLLAR

 

 

RESTRICTOR

 

 

 

 

 

SCREWS

 

 

 

 

FLAPPER

 

 

 

DOOR

 

 

SCREWS (2)

 

 

BOTTOM

 

 

 

OF FIREPLACE

 

EXHAUST

 

 

 

 

 

 

PORT

Figure 7.5

 

 

 

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. H • 11/08