Hitachi HTS541660J9SA00 General Operation Descriptions, Reset Response, Register Initialization

Models: HTS541640J9SA00 HTS541616J9SA00 HTS541680J9SA00 HTS541612J9SA00 HTS541660J9SA00

1 167
Download 167 pages 31.29 Kb
Page 48
Image 48
12 General Operation Descriptions
Power On Reset (POR)
COMRESET
Soft Reset (Software Reset)

Travelstar 5K160 (SATA) Hard Disk Drive Specification

12 General Operation Descriptions

12.1 Reset Response

There are three types of reset in ATA as follows:

The device executes a series of electrical circuitry diagnostics, spins up the HDA, tests speed and other mechanical parametric, and sets default values. COMRESET is issued in Serial ATA bus.

The device resets the interface circuitry as well as Soft Reset. SRST bit in the Device Control Register is set, then is reset.

The device resets the interface circuitry according to the Set Features requirement.

The actions of each reset are shown in “Reset Response Table” on Page 5

 

 

POR

 

 

 

Aborting Host interface

 

-

Aborting Device operation

-

Initialization of hardware

 

O

Internal diagnostic

 

O

Starting spindle motor

(*5)

Initialization of registers (*2)

 

O

Reverting programmed parameters to default

 

O

- Number of CHS (set by Initialize Device Parameter)

 

 

- Multiple mode

 

 

- Write cache

 

 

- Read look-ahead

 

 

- ECC bytes

 

 

- Volatile max address

 

 

Power mode

(*5)

Reset Standby timer value

 

o

 

 

 

O ---- execute

X ---- not execute

COMRESET

o

(*1)

x x x o (*6)

(*4)

o

12.1 Reset Response(*1) Execute after the data in write cache has been written. Soft Reset

o

(*1)

x

x

x

o

(*3)

(*4)

x

Note.

(*1) Execute after the data in write cache has been written.

(*2) Default value on POR is shown in “Default Register Values” on Page 5.

(*3) The Set Features command with Feature register = CCh enables the device to revert these parameters to the power on defaults.

(*4) In the case of sleep mode, the device goes to standby mode. In other case, the device does not change current mode.

(*5) According to the initial power mode selection.
(*6) See 5.15 Software Setting Preservation feature.

Figure 5 Reset Response Table

12.1.1Register Initialization

After power on, COMRESET, or software reset, the register values are initialized as shown in the following table.

Register

Default Value

Error

Diagnostic Code

Sector Count

01h

LBA Low

01h

LBA Mid

00h

LBA High

00h

Device

00h

Status

50h

 

48/167

Page 48
Image 48
Hitachi HTS541660J9SA00, HTS541640J9SA00 manual General Operation Descriptions, Reset Response, Register Initialization