Hitachi HTS541680J9SA00, HTS541640J9SA00, HTS541616J9SA00, HTS541660J9SA00 manual Idle E3h/97h

Models: HTS541640J9SA00 HTS541616J9SA00 HTS541680J9SA00 HTS541612J9SA00 HTS541660J9SA00

1 167
Download 167 pages 31.29 Kb
Page 91
Image 91
14.9 Idle (E3h/97h)

Travelstar 5K160 (SATA) Hard Disk Drive Specification

14.9 Idle (E3h/97h)

Command Block Output Registers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command Block Input Registers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Register

 

 

 

 

7

 

6

 

5

 

 

 

4

 

3

 

2

 

 

1

 

0

 

 

Register

 

 

 

7

6

 

 

 

 

5

 

4

3

 

2

 

1

 

0

Data

 

 

 

 

-

-

-

 

 

 

-

 

-

 

-

 

-

 

-

 

 

Data

 

 

 

 

-

-

 

 

 

-

 

-

-

 

-

 

-

 

-

Feature

 

 

 

 

-

 

-

 

-

 

 

 

-

 

 

-

 

-

 

 

-

 

-

 

 

Error

 

 

 

 

 

 

 

...See Below...

 

 

 

Sector Count

 

 

 

 

V

 

V

 

V

 

 

 

V

 

V

 

V

 

V

 

V

 

Sector Count

 

 

 

-

-

 

 

 

 

-

 

 

-

-

 

-

 

-

 

-

LBA Low

 

 

 

-

-

-

 

 

 

-

 

-

 

-

 

-

 

-

 

 

LBA Low

 

 

 

-

-

 

 

-

 

 

-

-

 

-

 

-

 

-

LBA Mid

 

 

 

 

-

 

-

 

-

 

 

 

-

 

 

-

 

-

 

 

-

 

-

 

 

LBA Mid

 

 

 

-

-

 

 

 

 

-

 

-

-

 

-

 

-

 

-

LBA High

 

 

 

-

-

-

 

 

 

-

 

-

 

-

 

-

 

-

 

 

LBA High

 

 

 

-

-

 

 

-

 

-

-

 

-

 

-

 

-

Device

 

 

 

 

-

-

-

 

 

 

-

 

-

 

-

 

-

 

-

 

 

Device

 

 

 

 

-

-

 

 

-

 

-

-

 

-

 

-

 

-

Command

 

 

 

1

1

1

 

 

 

0

0

0

 

1

 

1

 

 

Status

 

 

 

 

 

 

 

...See Below...

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error Register

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status Register

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

6

5

4

 

3

 

 

 

2

 

 

 

 

 

1

 

 

 

0

 

 

 

 

7

 

6

5

4

3

 

 

2

 

 

 

1

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CRC

 

UNC

0

IDN

 

0

 

 

ABT

 

 

T0N

 

 

AM

 

 

BSY

 

RDY

DF

DSC

DRQ

 

 

COR

IDX

 

ERR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

0

0

 

0

 

 

 

 

V

 

 

0

 

 

 

0

 

 

 

 

0

 

V

0

V

-

 

 

0

 

 

 

0

 

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 42 Idle Command (E3h/97h)

When the power save mode is Standby mode, the Idle command causes the device to enter performance Idle mode immediately, and set auto power down timeout parameter(standby timer). And then the timer starts counting down. When the device’s power save mode is already any idle mode, the device keep that mode.

When the Idle mode is entered, the device is spun up to operating speed. If the device is already spinning, the spin up sequence is not executed.

During Idle mode the device is spinning and ready to respond to host commands immediately.

Output Parameters To The Device

Sector Count Timeout Parameter. If zero, the timeout interval(Standby Timer) is disabled. If other than zero, the timeout interval is set for (Timeout Parameter x5) seconds.

The device will enter Standby mode automatically if the timeout interval expires with no device access from the host. The timeout interval will be reinitialized if there is a device access before the timeout interval expires.

91/167

Page 91
Image 91
Hitachi HTS541680J9SA00, HTS541640J9SA00, HTS541616J9SA00, HTS541660J9SA00, HTS541612J9SA00 manual Idle E3h/97h