Superflow-VC

Superflow-VC

Disposable Carbon Adsorber

Models SFVC*-xxxxxx (Where * indicates carbon type: 201, 202, 204, 205 or 209.

See P ice book.)

General

Flanders Superflow-VC Disposable Activated Carbon Adsorbers are designed for gaseous con- tamination control in both new and existing HVAC systems. Superflow-VC Adsorbers have total- detention capability with all air passing through the carbon beds. These adsorbers can help mitigate Indoor Air Quality problems in buildings where the air must be cleansed of gaseous contaminants. They are also useful in a variety of other applica- tions such as the protection of light industrial processes and works of art.

Construction

Superflow-VC Adsorbers consist of eight activated carbon-filled panels arranged in a V configuration and sealed with non-volatile adhesive into top and bottom injection molded ABS plastic end plates. The sealant completely eliminates bypass within the cell. The end plates incorporate a single head- er to position the cell in holding frames or si e access housings.

Extruded aluminum vertical struts close off the panel edges in front and are aerodynamically designed to minimize airflow restriction and turbu- lence. Vertical steel rods on the downstream side provide rigidity and minimize twisting nd r cking.

The activated carbon panels are constructed of one” (25 mm) thick moisture-resistant corrugated kraft honeycomb grids. The honeycomb is filled with granular activated carbon held in place by fine

mesh nylon screens glued to the grid. The screens act as a secondary prefilter and also as an afterfil- ter. The activated carbon media is premium HVAC grade virgin coconut shell granules wi h a minimum carbon tetrachloride (CTC) ac ivi y of 60% per ASTM D-3467. Granules are 4 x 8 US mesh size with a minimum apparent den ity of 0.49 g/mL. The minimum hardness is 97 per ASTM D-3802 and the minimum surface area is 1100 m2/g by the N2 BET test method.

Physical Data

Top and bottom end pl tes: High strength ABS plas- tic

Vertical struts: Aerodynamically-designed extruded aluminum

Vertical supports: Steel rods on downstream side

Carbon panels: Eight one inch (25 mm) moisture resistant corrugated kraft honeycomb grids filled with granular activated carbon media contained by fine mesh nylon screens on both air entering and leaving sides

Panel sealant: Non-volatile type applied along the entire periphery of the panel to eliminate air by- pass

Activated carbon media: Virgin coconut shell base,

4 x 8 US mesh size, minimum 60% CTC activity

Operating limits: 150°F (65°C) and 95% RH, non- condensing

Features and Ben fi s

Total detention mu i-panel design combines high adsorption effi- ciency with low pressure drop

Entire cell s d sposable so installation is clean, quick and easy

Installation lexibility: adsorbers are suitable for both initial and retrofit applications and in front or side access arrangements.

Gas ous contamination control can be applied to most HVAC air syst ms

Impregnated carbons are available for control of difficult contami- nants: H2S, acid gases, formaldehyde, ammonia, aldehydes and amines