Honeywell 11255 manual Pressure Drop, Effi ien y, Carbon Selection

Models: 11255

1 136
Download 136 pages 57.63 Kb
Page 114
Image 114
Pressure Drop

Pressure Drop

HMZD Panels can be incorporated into V shaped configurations with minimal pressure drop and impact on the system.

Please note that the breakthrough t st was based on continuous 100 ppm Hexane chal- lenge concentration. Testing conduct d at an independent lab on virgin coconut shell car- bon.

Effi ien y

HMZD p nels perform better than loose filled systems due to increased density of carbon and elimination of air bypass

Carbon Selection

In general, contaminants with a boiling point greater than 100 C can be effectively removed with carbon type 201.

Contaminants with a boiling point below 100 C require other available types of impregnated carbon such as type 202, 204, 205, 209.

Flanders - Foremost in Air Filtration