Honeywell 11255 manual Vaporclean Performance, Contaminant Matching, Sample Model Number

Models: 11255

1 136
Download 136 pages 57.63 Kb
Page 112
Image 112
Vaporclean Performance

Vaporclean Performance

The pressure drop of the Vaporclean is 0.35 inch w.g. at a face velocity of 500 fpm. The initial efficiency of the adsorber under the following conditions shall be met.

Contaminant

Challenge

Efficiency

Capacity @

 

Concentration

 

50% Efficiency

 

 

 

 

Toluene

25 ppm

>90%

560 grams

SO2

30 ppm

>90%

60 grams

NO2

5 ppm

>70%

100 grams

Formaldehyde

500 ppb

>80%

4 grams

 

 

 

 

Contaminant Matching

Match the Vaporclean media type to the contaminant of concern.

HC

 

Hydrocarbons

 

HCOH Formaldehyde

 

AG

Acid

Gases

 

NH3

 

Ammonia

 

O3

Ozone

Application Media

 

Animal Odors1090

 

Diesel Exhaust

1501

Cooking Odors

1501

Museums 1073

 

Sewer Odors1075

 

Sample Model Number

VC

Vaporclean

1501

Media type

16

24 ga

01

Frame Style

2424

Size

GD

Gasket

VC-1501-16-01-2424-GD

NOTE:

Represents a Vaporclean, 24 ga galvanized steel frame, single header style, gasketed downstream, with 1501 media. Actual filter size is 23-3/8 x 23-3/8 x 11-1/2”

1.The 16-01 indicates a header style filter and 16-00 indicates a box style filter. Other frame materials, frame styles and sizes are available. Consult the factory.

2.Maximum operating temperature is 120°F.

3.Frame Styl : 01 for Single Header or 00 for Box Style

4.Gask t: 00 for not gasket or GU for gasket upstream or GD for gasket downstream

Flanders - Foremost in Air Filtration

112

Corporate Headquarters, St. Petersburg, FL

Page 112
Image 112
Honeywell 11255 Vaporclean Performance, Contaminant Matching, Sample Model Number, Flanders - Foremost in Air Filtration