Index

Intellution, 17 Internet Protocol, 22 IP, 22

IP address, 15 IRTD, 68

isolation capacitor, 60 IT, 22

IT networking professional, 13

—J—

jumper, 63

Jumper Comb, 73, 75, 78, 80, 82 Jumper Combs, 61

jumpers, 14, 55, 56

—K—

Kepware, 17 key-tabs, 64

—L—

Label, 63 labels, 58 LAN, 15, 22 Layer, 25 Layer 2, 23 Layer 3, 23

LED Indications on Ethernet Hub, 121 LED Indications on I/O Module, 120 LED Indications on Main CPU, 119 LED Indications on Scanner Module, 120 LED Indicators, 118

lithium battery, 10

Local Area Network, 15, 22

—M—

MAC, 22

Master Control Relay, 45

Media Access Control, 22

Modbus mapping structure, 16

Mode switch, 10

MODE switch, 112

Mode Transitions, 112

Modem, 92, 93, 94, 95

Module Placement, 57

Module Wiring, 68

—N—

Network diagrams, 176 networking concepts, 22 Networking Device Types, 26 Networking Protocols, 22 Networking Terms, 24 Node Addressing, 22 nodes, 22

Null Modem Cable, 90

—O—

OFFLINE Mode, 110 OHMs Inputs, 68 OPC, 16

OPC server/client software, 17 Open Modbus/TCP protocol, 16 Operating Characteristics, 107

Operating Modes, 107

Orientation of Rack Mounting, 39

OSI Model, 22

—P—

Parallel processing, 3

PC hosts, 14

PC Hosts, 15

PC Modem Cable, 91

PDE, 15

Peer Data Exchange, 15 Peer-to-peer communication, 14 Personal Computer, 12

PlantScape SCADA or Vista Software, 17 Power DOWN, 107

Power Down / Power Up, 107 Power Supply, 9, 53, 54 Power Supply De-rating, 40 Power transitions, 107 Power UP, 107 PROGRAM Mode, 110 protocols, 22

PV Input Types and Ranges, 171

—R—

Rack Dimensions, 47 rack mounting, 52 Rack Options, 9 RAM, 107

Relay Output Module Wiring, 82 Removal and Insertion Under Power, 62 Removal and Replacement Procedures, 145 Repeater, 26

Replacing an I/O Module, 150 Replacing the Controller Module, 148 Replacing the Power Supply, 146 Replacing the Scanner Module, 149 RIUP, 62, 145, 150

Router, 15, 17, 18, 26 RS-232, 89, 90 RS-232 Modem, 12 RS-232 Port, 10 RS-485, 10, 100 RTD Input Wiring, 69 RTD Inputs, 68 RTU, 16

RUN Mode, 110

—S—

SCADA, 16

Scanner Diagnostics, 135 Scanner Module, 10 service provider, 18 shielded twisted pair, 44 Signal Grounding, 60

Simple Mail Transport Protocol, 18 Site and Equipment Preparation, 50 site diagrams, 176

Site Plan Documentation, 48, 49 SMTP, 18

sockets, 15 Source, 22

208HC900 Hybrid Controller Installation and User GuideRevision 5 9/03

Page 218
Image 218
Honeywell HC900 manual Operating Modes

HC900 specifications

The Honeywell HC900 is a robust control solution designed to meet the demands of process industries. This flexible and powerful platform provides a comprehensive set of features tailored for process control and monitoring applications. The HC900 is particularly suited for batch control, continuous processes, and discrete applications, making it a versatile choice for a variety of industries, including oil and gas, chemicals, and electricity generation.

One of the main features of the HC900 is its modular design. This allows users to customize their control systems by selecting from a range of I/O modules, communication options, and control strategies. The system supports both analog and digital inputs and outputs, enabling seamless integration with existing infrastructures. Additionally, the modular approach enhances scalability, allowing users to expand their systems as their needs evolve.

The HC900 is equipped with advanced control technologies, including adaptive control, multivariable control, and real-time data logging. These capabilities facilitate fine-tuned control over complex processes, improving efficiency and reducing waste. The system can manage multiple process loops simultaneously, providing operators with a holistic view of their operations.

Another significant characteristic of the HC900 is its intuitive user interface. The system features a graphical display that allows operators to monitor system performance easily and make adjustments quickly. This user-friendly design minimizes training requirements and encourages efficient operation across different experience levels.

Furthermore, the HC900 incorporates sophisticated data management tools. With built-in logging and reporting functions, users can track process variables and generate comprehensive reports for analysis and regulatory compliance. This data-centric approach fosters informed decision-making and enhances overall operational effectiveness.

From a communication standpoint, the HC900 supports a variety of protocols, making it compatible with many industry-standard devices. This interoperability ensures that users can integrate the HC900 into their existing systems without hassle, streamlining migration and upgrade processes.

Additionally, the HC900 is built with reliability in mind. Its rugged design ensures durability, capable of withstanding harsh environments while maintaining consistent performance.

In summary, the Honeywell HC900 stands out as a powerful and flexible control solution, equipped with modular design, advanced control technologies, and user-friendly interfaces that cater to the diverse needs of process industries. With its comprehensive data management capabilities and robust communications options, the HC900 is an excellent choice for organizations striving for efficiency and reliability.