Table of Contents

Recommended Programming Procedure

3

Relay Programming

25

Program Field Index

4

Relay Voice Descriptors

28

VISTA-50P/VISTA-50PUL Programming Form

5

Relay Voice Descriptors and Custom Word

 

Partition-Specific Fields

10

Substitutes Vocabulary

29

Custom Word Substitutes for VIP Module

 

Programming With #93 Menu Mode

12

 

Annunciation

30

Zone Programming

13

System Layout Worksheets

31

5800 Series Transmitters Loop Designations

15

Relay Devices Worksheets

39

Expert Mode Zone Programming

16

Scheduling Menu Prompts

41

Alpha Descriptors Programming

20

Scheduling Worksheets

42

Alpha Descriptor Vocabulary

23

VISTA-50P/VISTA-50PUL Summary of

 

Device Programming

24

 

Connections Diagram

47

 

 

The purpose of this document is to provide a quick and easy way to program your entire system. A recommended programming procedure is included, followed by a list of program fields with the corresponding program group they belong to (system-wide, partition-specific, scheduling, etc.). Two program forms are included. One contains all the programming fields, and the other contains the partition-specific fields. If you are setting up a single-partition system, the partition-specific fields become system-wide fields.

Following the program forms are system layout worksheets. We recommend that you use these sheets to plan your system before programming is performed. If you need further information about specific programming options, see the ADEMCO VISTA-50P/VISTA-50PUL Installation and Setup Guide.

Make sure that one two-line alpha keypad is connected to the control and is set to device address "00."

Single-Partition System

The system default is for a single-partition system. Use the VISTA-50P/VISTA-50PUL SINGLE PARTITION PROGRAMMING FORM when programming for single-partition usage. Follow the steps outlined in RECOMMENDED PROGRAMMING PROCEDURE of this document for proper programming procedure.

Multiple-Partition System

You must enter the number of partitions you are using in data field 2*00 to set the system for multiple partitions. Use the VISTA-50P/VISTA-50PUL SINGLE PARTITION and the PARTITION-SPECIFIC PROGRAM FORMS when programming the system for multiple partitions. Follow the steps outlined in RECOMMENDED PROGRAMMING PROCEDURE of this document for proper programming procedure.

SUMMARY OF PROGRAMMING COMMANDS

To enter program mode, enter installer code + [8] + [0] + [0]

To set standard defaults, press 97

To change to next page of program fields, press 94

To return to previous set of fields, press 99

To erase account and phone number field entries, press [] + field number + []

To assign zone descriptors, press #93 + follow menu prompts

To add custom words, press #93 + follow menu prompts

To enter Installer's Message, press #93 + follow menu prompts

To exit program mode, enter 99 OR 98: 99 allows re-access to programming mode by installer code. 98 prevents re-access to programming mode by installer code.

Standard default (97) values are shown in brackets [ ], otherwise default = 0.