Partition-Specific Fields
(Duplicate this page for each partition in the installation.)
To program these fields,
1.Press *91 to select a partition.
2.Enter a
3.Make the required entry.
4.Repeat steps
PARTITION #____ PROGRAM FIELDS
1st Page Fields | *87 | ENTRY WARNING | [1] | ||
| |||||
*09 ENTRY DELAY #1 | [02] |
| 1=continuous; 0=3 beeps |
|
00,
Maximum 03 for UL Listed installations.
*10 | EXIT DELAY #1 | [03] |
| 00, |
|
| Maximum 04 for UL Listed installations. |
|
*11 | ENTRY DELAY #2 | [06] |
| 00, |
|
| Maximum 03 for UL installations. |
|
*88 | BURG. ALARM COMM. DELAY |
| [0] | ||||||
| 1=16 seconds; 0=no delay. |
|
|
|
|
|
|
| |
| Must be "0" for UL installations. Must be “1” for SIA | ||||||||
| installations. |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
*90 | SEC. SUBS. ACCT # |
|
|
|
|
| |||
| Enter | [15 15 15 15] |
|
|
|
2nd Page Programming Fields (press *94)
*12 EXIT DELAY #2 | [08] |
00,
1*18 AFFECTS LOBBY | [0] |
Enter 1 if this partition affects the common lobby; enter 0 if it does not.
*13 ALARM SOUNDER DURATION | [04] |
Must be minimum 16 minutes for UL installations.
1*19 ARMS LOBBY | [0] |
Enter 1 if arming this partition attempts to arm lobby; enter 0 if it does not
*16 | CONFIRMATION OF ARMING DING | ||
| 1=enable; 0=disable. |
|
|
| Must be "1" for UL installations. |
|
|
*22 | KEYPAD PANIC ENABLES | [001] |
|
| |||
| 1=enable; 0=disable | 995 | |
*23 | MULTIPLE ALARMS |
|
|
| 1=yes; 0=no. |
|
|
| Must be 1 for UL installations. |
|
|
*29 | QUICK ARM |
|
|
| 1=yes; 0=no |
|
|
[0] |
| 1*20 | EXIT ERROR LOGIC ENABLE | [0] |
| |
|
| |||||
|
| 0=No; 1=Bypass E/E and Interior zones faulted after exit | ||||
|
|
|
| |||
|
|
|
| delay. |
|
|
|
|
| 1*21 | Must be "0" for UL installations. |
|
|
|
|
| EXIT DELAY RESET | [0] |
| |
|
|
|
| |||
|
|
| ||||
996 |
| 999 | 0=No; 1=Resets Exit Delay to programmed value after zone | |||
|
|
|
| |||
[1] |
|
| is closed and then faulted prior to end of exit delay. |
|
| |
|
|
|
| Must be "0" for UL installations. |
|
|
|
| 1*43 |
|
| ||
|
| PERM. KEYPAD BACKLIGHT | [0] |
| ||
|
|
| ||||
[1] |
|
| 1=enable; 0=disable. When disabled, display lights when | |||
|
| |||||
|
|
|
| any key is pressed, and turns off after period of keypad | ||
|
|
|
| |||
|
|
|
| inactivity. |
|
|
*32 | PRIM. SUBS. ACCT # |
|
|
|
|
|
|
|
| ||||
| Enter | [15 15 15 | 15] |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||||||
*38 | PREVENT ZONE XX BYPASS |
| [00] |
|
| ||||||||
| can be bypassed | ||||||||||||
*39 | ENABLE OPEN/CLOSE REPORT |
|
|
| [0] |
|
| ||||||
|
|
|
|
| |||||||||
| FOR INSTALLER CODE |
|
|
|
|
|
|
|
|
| |||
| 1=enable; 0=disable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
*84 | SWINGER SUPPRESSION |
| [01] |
|
|
Must be "00" (disabled) for UL installations..
*85 ENABLE DIALER REPORTS FOR PANICS & DURESS
1=enable; [0=disable]
995 996 999 Duress
1*45 | EXIT DELAY SOUNDING | [0] |
|
| |
| 1=enable; 0=disable. Produces quick beeping during exit |
| |||
| delay if enabled. |
|
|
|
|
1*47 | CHIME ON EXTERNAL SIREN | [0] |
|
| |
|
| ||||
| 1=enable; 0=disable |
|
|
|
|
1*52 | SEND CANCEL IF ALARM + OFF | [1] |
|
| |
|
| ||||
| 1=no restriction; 0=within Bell Timeout period only |
|
|
|
|
|
|
|
| ||
1*76 | ACCESS CONTROL RELAY FOR PART.[00] |
| |||
| Relay will be pulsed for 2 seconds whenever code + [0] is |
| |||
| pressed. Enter |
|
|
|
|
| Must be "00" for UL installations. |
|
|
|
|
– 10 –