Partition-Specific Fields

(Duplicate this page for each partition in the installation.)

To program these fields,

1.Press *91 to select a partition.

2.Enter a partition-specific field number (ex. *09).

3.Make the required entry.

4.Repeat steps 1-3 for each partition in the system.

PARTITION #____ PROGRAM FIELDS

1st Page Fields

*87

ENTRY WARNING

[1]

 

*09 ENTRY DELAY #1

[02]

 

1=continuous; 0=3 beeps

 

00, 02-15 times 15 seconds.

Maximum 03 for UL Listed installations.

*10

EXIT DELAY #1

[03]

 

00, 03-15 times 15 seconds.

 

 

Maximum 04 for UL Listed installations.

 

*11

ENTRY DELAY #2

[06]

 

00, 02-15 times 15 seconds.

 

 

Maximum 03 for UL installations.

 

*88

BURG. ALARM COMM. DELAY

 

[0]

 

1=16 seconds; 0=no delay.

 

 

 

 

 

 

 

 

Must be "0" for UL installations. Must be “1” for SIA

 

installations.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*90

SEC. SUBS. ACCT #

 

 

 

 

 

 

Enter 00-09; B-F (11-15)

[15 15 15 15]

 

 

 

2nd Page Programming Fields (press *94)

*12 EXIT DELAY #2

[08]

00, 03-15 times 15 seconds. Maximum 04 for UL installations.

1*18 AFFECTS LOBBY

[0]

Enter 1 if this partition affects the common lobby; enter 0 if it does not.

*13 ALARM SOUNDER DURATION

[04]

01-15 times 2 minutes.

Must be minimum 16 minutes for UL installations.

1*19 ARMS LOBBY

[0]

Enter 1 if arming this partition attempts to arm lobby; enter 0 if it does not

*16

CONFIRMATION OF ARMING DING

 

1=enable; 0=disable.

 

 

 

Must be "1" for UL installations.

 

 

*22

KEYPAD PANIC ENABLES

[001]

 

 

 

1=enable; 0=disable

995

*23

MULTIPLE ALARMS

 

 

 

1=yes; 0=no.

 

 

 

Must be 1 for UL installations.

 

 

*29

QUICK ARM

 

 

 

1=yes; 0=no

 

 

[0]

 

1*20

EXIT ERROR LOGIC ENABLE

[0]

 

 

 

 

 

0=No; 1=Bypass E/E and Interior zones faulted after exit

 

 

 

 

 

 

 

 

delay.

 

 

 

 

 

1*21

Must be "0" for UL installations.

 

 

 

 

 

EXIT DELAY RESET

[0]

 

 

 

 

 

 

 

 

996

 

999

0=No; 1=Resets Exit Delay to programmed value after zone

 

 

 

 

[1]

 

 

is closed and then faulted prior to end of exit delay.

 

 

 

 

 

 

Must be "0" for UL installations.

 

 

 

 

1*43

 

 

 

 

PERM. KEYPAD BACKLIGHT

[0]

 

 

 

 

[1]

 

 

1=enable; 0=disable. When disabled, display lights when

 

 

 

 

 

 

any key is pressed, and turns off after period of keypad

 

 

 

 

 

 

 

 

inactivity.

 

 

*32

PRIM. SUBS. ACCT #

 

 

 

 

 

 

 

 

 

Enter 00-09; B-F (11-15)

[15 15 15

15]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*38

PREVENT ZONE XX BYPASS

 

[00]

 

 

 

01-86; 000 if all zones (except fire zones)

can be bypassed

*39

ENABLE OPEN/CLOSE REPORT

 

 

 

[0]

 

 

 

 

 

 

 

 

FOR INSTALLER CODE

 

 

 

 

 

 

 

 

 

 

1=enable; 0=disable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*84

SWINGER SUPPRESSION

 

[01]

 

 

01-15 alarms;

Must be "00" (disabled) for UL installations..

*85 ENABLE DIALER REPORTS FOR PANICS & DURESS

1=enable; [0=disable]

995 996 999 Duress

1*45

EXIT DELAY SOUNDING

[0]

 

 

 

1=enable; 0=disable. Produces quick beeping during exit

 

 

delay if enabled.

 

 

 

 

1*47

CHIME ON EXTERNAL SIREN

[0]

 

 

 

 

 

1=enable; 0=disable

 

 

 

 

1*52

SEND CANCEL IF ALARM + OFF

[1]

 

 

 

 

 

1=no restriction; 0=within Bell Timeout period only

 

 

 

 

 

 

 

 

1*76

ACCESS CONTROL RELAY FOR PART.[00]

 

 

Relay will be pulsed for 2 seconds whenever code + [0] is

 

 

pressed. Enter 00-16; 00=none.

 

 

 

 

 

Must be "00" for UL installations.

 

 

 

 