Honeywell Ademco Vista Series Commercial Burglary Partitioned Security System With Scheduling

Models: Vista-50P/Vista-50PUL Ademco Vista Series Commercial Burglary Partitioned Security System With Scheduling

1 48
Download 48 pages 30.57 Kb
Page 47
Image 47
— 47 —

— 47 —

 

 

WARNING: OWNER'S INSTRUCTION NOTICE NOT TO BE REMOVED

 

 

 

 

WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM.

 

 

NOTES:

1. Zone 1 may be selected for EOLR supervised

4. Zone 8 supports 2-wire latching type glass break detectors.

 

J7 Header

 

 

J8 Header

 

 

 

 

 

 

 

 

 

 

MAKE CONNECTIONS USING

 

 

 

or normally closed (no EOLR) operation via

 

See Installation and Setup Guide for recommended type

 

 

1. Not Used

 

 

1. In 2 (Printer DTR)

Optional programming:

 

 

 

 

No. 4142TR CABLE

 

 

 

cut jumper. (Cut red jumper for normally closed

and maximum number of detectors supported.

 

 

 

2. Ground-

 

 

2.

Ground

 

Out 1: Open/close or keypad-like sounding

 

Blue

 

 

operation. Do not cut for Fire Usage). Zones 2-8

5. Cut blue jumper to disable supervision of alarm sounder output.

 

3. Out 1 (Ground Start)

3. In 3 (1361X10 sync)

Out 2: Armed LED

 

 

 

 

 

 

 

 

may be selected for either operation via program

 

4. Ground-

 

 

4. In 4 (1361X10 sync)

Out 4: Ready LED

 

 

 

 

 

J8

Jumper

 

 

 

 

 

 

 

 

 

 

 

 

field *41.

 

 

 

 

 

Leave jumper intact to supervise output. (See Installation and

 

 

 

 

 

 

 

 

(note 5)

 

 

 

 

 

 

 

 

5. Out

2 (fire)

 

5.

Ground

 

Ratings for Out 1:

 

 

 

 

 

 

 

 

 

 

2. Zone 1 supports 2-wire smoke detectors.

 

Setup Guide for Programming and Wiring Instructions).

 

 

6. Ground-

 

 

6. Out 5 (1361X10 data) Active: 10VDC-13.8VDC through 4k OHMS

1 2 3 4 5 6 7 8 9

 

 

 

See Installation and Setup Guide for recommended

 

 

 

 

 

 

 

 

 

7. Out

3 (burg/aud. panic) 7.

Out 6 (Printer RXD)

Not Active: 100 OHMS to ground

 

 

 

 

 

BATTERY

type and maximum number of detectors supported.

 

 

 

 

 

 

 

 

 

8. Ground

 

 

8.

Ground

 

Ratings for out 2-4:

 

 

 

 

 

 

Connect to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9. Out 4 (silent panic/

9.

Ground

 

Active: 10VDC-13.8VDC through 5k OHMS

 

 

TABS

3. Zone 7 may be used for remote keyswitch

 

 

 

 

 

 

 

 

 

 

 

Not Active: 1k OHMS to ground

 

 

J7

12VDC,

 

 

 

 

 

 

 

 

 

 

 

duress)

 

 

 

 

 

 

 

 

 

(+)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4AH - 17.2AH

arming/disarming. See Installation and Setup Guide

 

 

 

Red Jumper

 

 

 

 

 

(Refer to Installation Instructions for information concerning Direct Wire

 

 

 

1 2 3 4 5 6 7 8 9

RED

for wiring instructions.

 

 

 

 

 

 

 

 

 

 

 

 

Downloading and printer connections using the 4100SM Serial Module.)

 

 

 

SEALED LED

 

 

 

 

 

 

 

(note 1)

 

 

 

 

 

 

 

 

ACID BATTERY

 

 

 

 

 

 

 

 

 

 

 

ZONE 2 ZONE 3

ZONE 4 ZONE 5

ZONE 6 ZONE 7

 

ZONE 8 ZONE 9

 

 

 

 

 

 

 

 

 

EARTH GROUND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHARGING

 

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

 

21

22

23

24

25

26

 

27

28

 

29

30

Connect to good earth

VOLTAGE

 

(–)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ground to maintain im-

13.7VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

munity to transients.

See

 

BLK

 

 

 

 

 

 

 

 

 

 

ZONE 1

 

 

 

 

 

 

 

 

 

 

 

 

 

(BROWN)

(GRAY)

(GREEN)

 

(RED)

 

See Instructions for

Instructions for

 

 

 

 

 

 

 

in

out

 

 

+

+

 

 

+

+

 

 

 

 

 

 

 

 

DOC LOAD NO.: 5

required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RING

TIP

RING

 

Installation

 

 

 

CONNECTION

 

 

 

 

 

 

 

SMOKEWIRE-2 DETECTORLOOP NO/NCsupportsBurgcontacts)

 

 

 

 

 

 

 

 

 

 

LATCHINGTYPE GLASS

DETECTORBREAK LOOP

ProgrammableResponse (Fast/Normal)Loop

 

POLLINGLOOP

TIP

 

 

 

proper grounding.

ADEMCO No.1361

 

NO

 

 

for max. # of keypads

 

2k EOLR

 

2k EOLR

 

2k EOLR

 

2k EOLR

 

 

 

THIS EQUIPMENT SHOULD BE INSTALLED

capacity

Connect to

 

 

 

 

 

+

Data

Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Handset

 

Incoming

 

 

Replace

24hr. 120VAC,

 

 

 

 

 

 

 

 

 

N.C.

 

N.C.

 

 

N.C.

 

N.C.

 

 

 

 

 

 

 

 

 

Phone Line

WARNING: TO PREVENT

every

60 Hz Outlet

 

 

 

 

 

Red

Blk

Grn

Yel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RISK OF ELECTRICAL

3 years

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Telephone connections

 

SHOCK, DISCONNECT

 

 

 

 

 

 

 

 

REMOTE KEYPAD/DEVICES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

using Ademco No. 620

 

 

 

 

 

 

 

 

 

(Addressable keypads) only

 

 

N.O.

 

N.O.

 

 

N.O.

 

N.O.

 

 

 

 

 

 

RJ31X direct connect

 

TELCO JACK BEFORE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cord.

 

 

SERVICING THIS PANEL.

TRANSFORMER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16.5VAC, 40VA

 

 

 

 

 

See Installation Instructions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(IN CANADA USE

 

BELL

 

 

and for max. wire run length.

 

(Also

(note 1)

 

(note 1)

 

 

(note 1)

 

(note 1,3)

+

+

 

4208U

 

IN ACCORDANCE WITH THE NATIONAL

 

No. 1361CN)

 

+

 

 

 

 

 

 

 

+

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OR 1361X10

 

 

 

 

 

 

+

Fire

 

 

 

 

 

GLASS

 

 

 

 

 

 

FIRE PROTECTION ASSOCIATION'S

IF X-10 DEVICES

 

+

 

AUXILARY POWER OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STANDARD 72, CHAPTER 2 (NATIONAL FIRE

WILL BE USED

 

 

 

 

 

Usage

 

 

 

 

 

 

 

 

BREAK

 

 

 

 

 

 

 

 

 

 

 

 

 

9.6VDC - 13.8VDC,

 

 

 

 

 

 

 

N.C.

 

N.C.

 

 

 

 

 

 

 

 

 

 

 

PROTECTION ASSOC., BATTERYMARCH

 

 

NOTE:

 

 

 

 

750mA maximum

 

 

 

 

SMOKE

 

 

 

 

 

 

 

 

 

 

N.C.

 

4192SD

 

PARK. QUINCY, MA. 02269). PRINTED

 

 

 

 

 

 

Note: Include current drawn

 

 

 

 

 

 

 

 

 

 

 

 

N.C.

 

 

SMOKE

 

WHEN POWERING UP THE PANEL,

 

 

 

by keypads and polling loop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INFORMATION DESCRIBING PROPER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLUG THE TRANSFORMER IN BEFORE

SIREN

 

devices when making

 

 

 

 

 

 

 

N.O.

 

N.O.

 

 

 

 

 

 

 

 

 

 

 

INSTALLATION, OPERATION, TESTING,

CONNECTING THE BATTERY.

 

auxiliary power calculations.

 

N.C.

 

 

 

 

 

 

 

 

 

 

 

 

 

4190

 

 

 

 

 

 

 

 

 

 

 

 

N.O.

 

N.C.

 

 

 

MAINTENANCE, EVACUATION PLANNING

 

 

 

ALARM SOUNDER OUTPUT

 

 

 

 

 

 

Burg.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SN

 

AND REPAIR SERVICE IS TO BE

 

 

 

10VDC - 13.8VDC, 1.7A max

 

 

 

 

 

 

Usage

 

2k EOLR

 

2k EOLR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2k EOLR

 

 

 

 

 

 

PROVIDED WITH THIS EQUIPMENT.

 

 

 

 

For Household Fire Installations,

 

 

 

 

N.O.

 

 

(note 1)

 

(note 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(note 1,4)

 

 

 

USE UL LISTED ENERGY CABLE FOR ALL CONNECTIONS

 

 

 

 

supervise alarm sounder output (Note 5)

 

 

 

 

 

Zone resistance (Excluding EOLR):

 

 

 

 

 

 

 

 

 

 

 

and limit combined alarm sounder,

 

 

 

2k EOLR

 

ZONE 1,8: 100 OHMS MAXIMUM

 

 

Polling loop rating: 64mA max. See

 

 

 

 

 

 

 

 

 

 

 

 

aux power and polling loop current to 750mA.

 

 

ALL OTHER ZONES: 300 OHMS MAXIMUM

Installation Instructions for maximum

 

COMPLIES WITH FCC RULES, PART 68

 

 

 

 

 

 

 

 

 

 

 

 

(note 1,2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone response time:

 

 

 

 

number of devices supported and

 

 

FCC REGISTRATION NO. AC398U-68192-AL-E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZONES 1-8: 350mSec-500mSec

 

 

maximum wire run length.

 

 

 

RINGER EQUIVALENCE: 0.7B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZONE 9: Programmable for

 

 

 

CONNECTION OF THE FIRE ALARM SIGNAL

 

THIS DEVICE COMPLIES WITH PART 15 OF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fast: 10mSec-15mSec

 

 

TO A FIRE ALARM HEADQUARTERS OR A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FCC RULES. OPERATION IS SUBJECT TO THE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal: 350mSec-500mSec

 

CENTRAL STATION SHALL BE PERMITED

 

 

 

 

 

 

 

 

 

 

 

 

ALL CIRCUITS ARE

 

 

 

 

(default response)

 

 

ONLY WITH THE APPROVAL OF THE LOCAL

 

FOLLOWING TWO CONDITIONS: (1) THIS DEVICE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTHORITY HAVING JURISDICTION. THE

 

MAY NOT CAUSE HARMFUL INTERFERENCE, AND

 

 

 

 

 

 

 

 

 

 

 

POWER LIMITED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BURGLAR ALARM SIGNAL SHALL NOT BE

 

(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONNECTED TO A POLICE EMERGENCY

 

RECEIVED, INCLUDING INTERFERENCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NUMBER.

 

 

 

 

 

 

THAT MAY CAUSE UNDESIRED OPERATION.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADEMCO VISTA-50P/VISTA-50PUL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SUMMARY OF CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

V50P_PUL-SOC-V1

VISTA-50P/VISTA-50PUL Summary of Connections Diagram

Page 47
Image 47
Honeywell Ademco Vista Series Commercial Burglary Partitioned Security System With Scheduling, Vista-50P/Vista-50PUL manual