5800 Series Transmitters Loop Designations

 

LOOP 3

 

 

 

 

LOOP 2

 

 

 

 

LOOP 1

 

 

 

 

 

 

 

LOOP

 

LOOP 4

 

 

1

 

 

 

 

 

YOU MUST

 

 

 

 

ENROLL THIS

 

 

 

 

BUTTON

 

 

 

5801

 

 

5 8 0 2 M N

ENROLL AS "UR" OR "RF"

ENROLL AS "UR" OR "RF"

YOU MUST

LOOP 3

 

 

 

 

 

 

 

ENROLL THIS

 

 

 

 

BUTTON

LOOP 2

 

 

 

LOOP 4

 

 

 

LOOP 1

 

 

 

 

 

 

LOOP 2

 

 

 

 

YOU MUST

 

 

 

 

ENROLL THIS

 

 

 

 

BUTTON

 

 

 

 

LOOP 4

 

 

 

 

LOOP 1

5 8 0 4

LOOP 3

 

 

 

 

••

 

ENROLL

 

 

 

•••••

SET

 

 

• ••• •

AS "BR"

 

• •

HOUSE

 

 

 

 

 

CODE

 

 

5804BD

 

 

 

ENROLL AS "BR"

 

LOOP

 

 

 

 

1

 

 

 

5809

 

 

 

 

ENROLL AS "RF"

 

 

 

 

 

 

 

 

LOOP 2

 

 

 

 

(REED)

LOOP

 

 

 

 

1

 

 

LOOP 1

 

 

 

 

(TERMINALS)

5808

 

5 8 1 6

 

ENROLL AS "RF"

 

ENROLL AS "RF"

 

 

LOOP 2

 

LOOP 1

 

 

(REED)

 

 

 

 

(PRIMARY)

 

 

 

 

 

 

 

 

LOOP 2

 

 

 

 

(AUX. CENTER)

 

 

LOOP 1

 

 

 

 

(TERMINALS)

LOOP 3

 

 

 

 

ALTERNATE

 

 

 

(AUX. RIGHT)

POSITION

 

5 8 1 6 M N

 

5 8 1 7

FOR LOOP 2

 

 

 

ENROLL AS "RF"

 

ENROLL AS "RF"

 

 

 

 

LOOP 2

 

LOOP

 

 

(REED)

 

 

LOOP 1

 

 

2

 

 

 

 

(TERMINALS)

 

 

(REED)

 

 

 

 

 

 

 

 

 

 

 

LOOP 1

 

 

 

LOOP 3

(INTERNAL

 

 

(TERMINALS)

SHOCK

 

 

 

 

SENSOR)

LOOP 3

 

 

 

 

(TERMINALS)

 

 

 

 

 

5 8 1 9

 

5819S (WHS & BRS)

ENROLL AS "RF"

 

ENROLL AS "RF"

 

5 8 2 7

 

 

5 8 2 7 B D

SET HOUSE CODE

 

SET HOUSE CODE

LOOP 1 (MOTION)

(Green) (Red) (Yellow)

5850 (GBD)

5 8 9 0

ENROLL AS "RF"

ENROLL AS "RF"

5800_trans_loop-V0

Note: For information on any transmitter not shown above, refer to the instructions accompanying that transmitter for details regarding loop numbers, etc.

 

 

UL

The 5802MN, 5802MN2, 5804, 5804BD, 5814, 5816TEMP, 5819, 5819WHS & BRS, 5827BD,

 

 

and 5850 transmitters are not intended for use in UL installations.

 

 

 

 

 

 

 

 

 

 

 

 

 

PROMPT

 

 

EXPLANATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XMIT TO CONFIRM PRESS TO SKIP

Entd A022-4063 1

Rcvd A022-4064

Confirmation Option: This prompt only appears if you answered “Yes” at the first prompt. The system enters a confirmation mode so that the operation of the actual programmed input can be confirmed. Activate the loop input or button that corresponds to this zone. At any time during this step, you may press the [] key on the keypad to save the serial and loop number combination without confirming.

If the serial number transmitted does not match the serial number entered, a display similar to the one at the left appears. If the loop number does not match, it is also displayed.

If so, activate the loop input or button on the transmitter once again. If a match is not obtained (i.e., summary display does not appear), press the [#] key twice and then enter or transmit the correct serial number.

10 ZT P RC In L

03 1 3C RF 1s

If the serial number transmitted does match the serial number entered, the system beeps 3 times and a summary display appears, showing that zone’s programming. Note that an “s” indicates that a transmitter’s serial number has been enrolled.

Press [] to accept the zone information.

– 15 –

Page 15