Honeywell Vista-50P/Vista-50PUL Zt = Zone Type/System Operation, P = PARTITION No. 1-8,0 = Any

Models: Vista-50P/Vista-50PUL Ademco Vista Series Commercial Burglary Partitioned Security System With Scheduling

1 48
Download 48 pages 30.57 Kb
Page 40
Image 40
ZT = ZONE TYPE/SYSTEM OPERATION

ZT = ZONE TYPE/SYSTEM OPERATION

Choices for Start/Stop Zone Types and System Operations:

00

= No Response (Not Used)

 

23

= No Alarm Response

 

43

= Communication failure

01

= Entry/Exit #1

31

= End of Exit Time

44

= RF Low Battery

02

= Entry/exit #2

32

= Start of Entry Time

45

= Polling Loop Failure

03

= Perimeter

33

= Any Burglary Alarm

51

= RF Receiver Failure

04

= Interior Follower

 

 

= Code + [#] + 71 Key Entry

 

 

= Kissoff

34

52

05

= Trouble Day/Alarm Night

35

= Code + [#] + 72 Key Entry

54

= Fire Zone Reset

06

= 24-Hr. Silent

 

 

= At Bell Timeout **

 

 

= Disarm + 1 Minute

36

55

07

= 24-Hr. Audible

37

= 2 Times Bell Timeout **

56

= XX Minutes (enter XX in field 1*74) *

08

= 24-Hr. Auxiliary

38

= Chime

57

= YY Seconds (enter YY in field 1*75) *

09

= Fire Alarm or Trouble

39

= Fire Alarm

58

= Duress

10

= Interior W/Delay

40

= Bypassing

60

= Audio Alarm Verification (must be

20

= Arming-STAY***

41

= AC Power Fail

 

 

selected for both START and STOP

21

= Arming-AWAY****

42

= System Battery Low

 

 

operation)

22

= Disarming (Code + Off)

 

 

 

 

 

 

NOTE: Any zone in "ZT" for Start, going into alarm, fault, or trouble will activate the relay.

Any zone in "ZT" for Stop, that restores will stop the relay action.

*Stop condition only

**Or at Disarming, whichever occurs earlier

***The output also activates when the partition is armed in the INSTANT mode

****The output also activates when the partition is armed in the MAXIMUM mode

P = PARTITION No. 1-8, 0 = Any

ZONE LISTS FOR OUTPUT DEVICES – Programmed in the #93 Menu Mode in the Output Programming Section. Fill in the required data on the worksheet below and follow the procedure shown earlier in this Programming Guide as you enter the data during the displays and prompts that appear in sequence. Up to 8 zone lists may be created

Note: Record desired zone numbers below. More or fewer boxes than shown may be needed, as any list may include any or all of system's zone numbers.

Zone List 1: Started or stopped by zone numbers (enter 00 to end entries).

Zone List 2: Started or stopped by zone numbers (enter 000 to end entries).

Zone List 3: Started or stopped by zone numbers (enter 000 to end entries).

Zone List 4: Started or stopped by zone numbers (enter 000 to end entries).

Zone List 5: Started or stopped by zone numbers (enter 00 to end entries).

Zone List 6: Started or stopped by zone numbers (enter 000 to end entries).

— 40 —

Page 40
Image 40
Honeywell Vista-50P/Vista-50PUL manual Zt = Zone Type/System Operation, P = PARTITION No. 1-8,0 = Any