2*06 AUTO-ARM WARNING PERIOD

[15]

 

 

 

 

 

This is the time during which the user is warned to exit the premises prior to the auto-arming of the system (beeps every

15 seconds; "ALERT" displayed). Enter 01-15 minutes.

00=instant at end of arming delay.

 

 

 

 

2*07 AUTO-DISARM DELAY

[15]

 

 

 

 

 

This is the time between the end of the disarming window and the start of auto-disarming. Enter 01-14 times 4 minutes; 00=instant at end of window; 15=no auto-disarm.

2*08 ENABLE FORCE ARM FOR AUTO-ARM [0]

0=disable; 1=enable

2*09 OPEN/CLOSE REPORTS BY EXCEPTION [0]

1=enable; 0=disable

If enabled, only openings and closings occurring outside the scheduled opening/closing windows will trigger dialer reports. Opening reports will also be suppressed during the closing window, in order to prevent false reports when the user arms the system and then reenters the premises to

retrieve a forgotten item.

2*10 ALLOW DISARMING ONLY DURING

[0]

 

 

 

 

 

 

 

 

ARMING/DISARMING WINDOWS

0=disable; 1=enable

See system-wide field 2*11 if enabling field 2*10. This feature adds high security to the installation.

2*11 ALLOW DISARM OUTSIDE WINDOW

[0]

IF ALARM OCCURS

Used only if field 2*10 (partition-specific field) is set to "1." If this field is enabled ("1") the system can be disarmed outside the disarm window if an alarm has occurred. If "0," disarming can only be done during the disarm window. If field 2*10 is set to "0" for a partition, this field has no effect for that partition.

2*13 2*14 SCHEDULING RELATED REPORT CODES

Enter 00-09; B-F (11-15).

Default = 00 for all reports

2*13 1st Digit 2*14 2nd Digit

2*18

ENABLE GOTO FOR THIS PARTITION

[0]

 

 

 

 

 

 

 

 

 

 

 

 

1=Allow log-on from other partitions; 0=disable

 

 

 

2*19

USE PARTITION DESCRIPTORS

 

 

[0]

 

 

 

 

 

 

 

0=disable; 1=enable

 

 

 

 

 

2*20

ENABLE J7 TRIGGERS FOR PARTITION

[1]

 

 

 

 

 

 

 

 

 

 

 

 

0=disable for displayed partition; 1=enable for displayed

 

partition

 

 

 

 

 

2*21

ENABLE SUPERVISION PULSES FOR LRR

 

 

 

 

 

 

 

 

 

 

 

TRIGGER OUTPUTS

[000]

 

 

 

Used for supervised connection to 7920SE. F

B

P

 

Enter 0 to disable or 1 to enable the listed outputs.

 

 

 

F= Fire; B= Burglary; P= Silent Panic/Duress.

Must be 1 for UL. Installations.

SUMMARY OF PROGRAMMING COMMANDS

To enter program mode, enter installer code + [8] + [0] + [0]

To set standard defaults, press *97

To change to next page of program fields, press *94

To return to previous set of fields, press *99

To erase account and phone number field entries, press [*] + field number + [*]

To assign zone descriptors, press #93 + follow menu prompts

To add custom words, press #93 + follow menu prompts

To enter Installer's Message, press #93 + follow menu prompts

To exit program mode, enter *99 OR *98: *99 allows re- access to programming mode by installer code. *98 prevents re-access to programming mode by installer code.

Early Opening

Early Closing

Late Opening

Late Closing

No Opening (late to open)

No Closing (late to close)

Auto-Arm Failure

Access Schedule Changed