*39 | ENABLE OPEN/CLOSE REPORT FOR | [0] |
|
|
| ||||
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
| INSTALLER CODE 1=enable; 0=disable |
|
|
|
|
| |||
*40 | OPEN/CLOSE REPORT FOR KEYSWITCH | [0] |
|
|
| ||||
|
|
| |||||||
| 1=enable; 0=disable |
|
|
|
|
|
|
|
|
*41 | NORMALLY CLOSED or EOLR (Zones | [1] |
|
|
| ||||
|
|
| |||||||
| 1=N.C.loops; 0=EOLR supervision. |
|
|
|
|
|
|
|
|
| Must be "0" for UL installations. |
|
|
|
|
|
|
|
|
*42 | DIAL TONE PAUSE |
|
|
| [0] |
|
|
| |
|
|
|
|
|
| ||||
| 0=5 seconds; 1=11 seconds; 2=30 seconds. |
|
|
|
|
| |||
| Must be "0" UL Installations. |
|
|
|
|
|
|
|
|
*43 | DIAL TONE DETECTION |
|
|
| [1] |
|
|
| |
|
|
|
|
|
| ||||
| 1=wait for true dial tone; 0=pause, then dial |
|
|
|
|
| |||
|
|
|
|
|
|
|
| ||
*44 | RING DETECTION COUNT | [00] |
|
| |||||
|
|
|
|
|
| ||||
| Must be "00" for UL Burglary. |
|
|
|
|
|
|
|
|
*45 | PRIMARY FORMAT |
|
|
| [1] |
|
|
| |
|
|
|
|
|
| ||||
| 0=Low Speed; 1=Contact ID; 2=ADEMCO High Speed; | ||||||||
| 3= ADEMCO Express |
|
|
|
|
|
|
|
|
*46 | LOW SPEED FORMAT (Primary) |
|
|
| [0] |
|
|
| |
|
|
|
|
|
| ||||
| 0= ADEMCO Low Speed; 1=Sescoa/Radionics |
|
|
|
|
| |||
*47 | SECONDARY FORMAT |
|
|
| [1] |
|
|
| |
|
|
|
|
|
| ||||
| 0=Low Speed; 1=Contact ID; 2= ADEMCO High Speed; | ||||||||
| 3= ADEMCO Express |
|
|
|
|
|
|
|
|
*48 | LOW SPEED FORMAT (Sec.) |
|
|
| [0] |
|
|
| |
|
|
|
|
|
| ||||
| 0= ADEMCO Low Speed; 1=Sescoa/Radionics |
|
|
|
|
| |||
*49 | CHECKSUM VERIFICATION | [0] [0] |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| 1=yes; 0=no | Prim |
|
|
| Sec | |||
*50 | SESCOA/RADIONICS SELECT |
|
|
| [0] |
|
|
| |
|
|
|
|
|
|
*58 SUPERVISORY AND RESTORE CODES FOR ZONES
|
|
|
| |||||
Alarm Rst | Trbl |
| Trbl Rst |
| Byp |
| Byp Rst |
*59 *62 ALARM REPORT CODES & ID DIGITS FOR ZONES 17-32.
Skip these fields. Use #93 Menu Mode, Zone Programming to program the report codes.
*63 SUPERVISORY AND RESTORE CODES FOR ZONES
|
|
|
| |||||
Alarm Rst | Trbl |
| Trbl Rst |
| Byp |
| Byp Rst |
*64 *67 ALARM REPORT CODES & ID DIGITS FOR ZONES 33-48.
Skip these fields. Use #93 Menu Mode, Zone Programming to program the report codes.
*68 SUPERVISORY AND RESTORE CODES FOR ZONES
|
|
|
| |||||
Alarm Rst | Trbl |
| Trbl Rst |
| Byp |
| Byp Rst |
*69 *72 ALARM REPORT CODES & ID DIGITS FOR ZONES 49-64.
Skip these fields. Use #93 Menu Mode, Zone Programming to program the report codes.
*73 SUPERVISORY AND RESTORE CODES FOR ZONES
|
|
|
| |||||
Alarm Rst | Trbl |
| Trbl Rst |
| Byp |
| Byp Rst |
*74 *77 ALARM REPORT CODES & ID DIGITS FOR ZONES 81-99.
Skip these fields. Use #93 Menu Mode, Zone Programming to program the report codes.
*78 SUPERVISORY AND RESTORE CODES FOR ZONES
1=Sescoa; 0=Radionics |
|
*51 DUAL REPORTING | [0] |
1=yes; 0=no If used with Spilt Reporting "1" option (1*34), alarms and alarm restores go to both primary & secondary numbers, while all other reports go to secondary only. If used with Split Reporting "2" option, alarms and alarm restores go to both, open/close and test messages go to secondary only, while all other reports go to primary.
*52 STANDARD/EXPANDED REPORT FOR PRIMARY
[0 0 0 0 0 0]
Alarm Rstr Byp Trbl O/C LoBat
0=standard; 1=expanded;
Note: Expanded overrides 4+2 format.
*53 STANDARD/EXPANDED REPORT FOR SECONDARY
[0 0 0 0 0 0]
Alarm Rstr Byp Trbl O/C LoBat 0=standard; 1=expanded;
*54 *57 ALARM REPORT CODES & ID DIGITS FOR ZONES 01-16.
Skip these fields. Use #93 Menu Mode, Zone
Programming to program the report codes.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
| Alarm Rst | Trbl |
| Trbl Rst | |||||||||||||
ZONE TYPE RESTORE ENABLES |
|
|
|
| ||||||||||||||||||
*79 FOR ZONE TYPES |
|
|
|
|
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 | 2 | 3 | 4 | 5 |
|
|
| 6 |
|
| 7 | 8 |
|
1=enable; [0=disable]
*80 FOR TYPES 9, and 10
1=enable; [0=disable]
| ||
Byp |
| Byp Rst |
9 10
– 6 –