| EXCEL 10 W7761A INPUT/OUTPUT DEVICE |
| |
|
|
|
|
| Table 8. Excel 10 W7761A Device Ordering Information (Continued). |
| |
Part Number | Product Description | Comments |
|
|
|
|
|
| Sensors (Continued): |
|
|
|
|
|
|
C7031J1050 | Averaging Discharge/Return Air Temperature | Duct element cord length 12 ft. (3.7m) |
|
| Sensor. 20 Kohm NTC |
|
|
|
|
|
|
C7031B1033 | Discharge Air or Hot Water Temperature Sensor. | Use 112622AA Immersion Well |
|
| 20 Kohm NTC |
|
|
|
|
|
|
C7031C1031 | Duct Discharge/Return Air Sensor. 20 Kohm | 18 in. (457mm) insertion length. |
|
|
|
|
|
C7031D1062 | Hot or chilled Water Temperature Sensor. 20 Kohm | — |
|
| NTC |
|
|
|
|
|
|
C7031K1017 | Hot or chilled Water Temperature Sensor. 20 Kohm |
| |
| NTC |
|
|
|
|
|
|
C7100A1015 | Averaging Discharge/Return Air Temperature | 13 in. (330mm) insertion length. |
|
| Sensor. PT3000 |
|
|
|
|
|
|
C7170A1002 | Outdoor Air Temperature Sensor. PT3000 | — |
|
|
|
|
|
| Echelon® Based Components and Parts: |
|
|
Q7750A1003 | Excel 10 Zone Manager | Free Topology Tranceiver (FTT) |
|
|
|
|
|
Q7751A2002 | Router | (FTT) |
|
|
|
|
|
Q7752A2001 | Serial Interface | (FTT) |
|
|
|
|
|
Q7740A1008 | Excel 10 | Used to extend the length of the |
|
|
| Contains built in termination modules. |
|
|
|
|
|
Q7740B1006 | Excel 10 | Used to extend the length of the |
|
|
| Contains built in termination modules. |
|
|
|
|
|
XD 505A | Standard | — |
|
|
|
|
|
XD 508 |
|
| |
| rate) | — |
|
|
|
|
|
209541B | Termination Module | One or two required per |
|
|
|
|
|
205979 | Operator Terminal Cable for | Serial interface to wall module or controller |
|
|
|
|
|
| Accessories: |
|
|
|
|
|
|
EL7680A1008 | Wall Mounted Wide View Infrared Occupancy | — |
|
| Sensor |
|
|
|
|
|
|
EL7628A1007 | Ceiling Mounted Infrared Occupancy Sensor | — |
|
|
|
|
|
EL7611A1003, | Ultrasonic Occupancy Sensors |
|
|
EL7612A1001 |
| — |
|
|
|
|
|
EL7630A1003, | Power Supply/Control Units for Occupancy sensors |
|
|
EL7621A1002, |
| — |
|
EL7621A1010 |
|
|
|
|
|
|
|
C7400A1004 | Solid State Enthalpy Sensor (4 to 20 mA) | For outdoor and return air enthalpy |
|
|
|
|
|
C7600B1000 | Solid State Humidity Sensor (2 to 10 V) | For outdoor and return air humidity |
|
|
|
|
|
C7600C1008 | Solid State Humidity Sensor (4 to 20 mA) | For outdoor and return air humidity |
|
|
|
|
|
C7600C1018 | Solid State Humidity Sensor (2 to 10 V) | For outdoor and return air humidity |
|
|
|
|
|
Pneumatic Retrofit Transducers. | Use to control Pneumatic reheat valves |
| |
Select pressure range: (010) 0 to 10 psi (68.97 kPa) |
|
| |
| or (020) 0 to 20 psi (137.93 kPa). |
|
|
|
|
|
|
MMCA530 | DIN rail adapter for MMC325 Transducers | — |
|
|
|
|
|
MMCA540 | Metal enclosure for MMC325 Transducers | — |
|
|
|
|
|
ML7984B3000 | Valve Actuator Pulse Width Modulation (PWM) | Use with V5011 or V5013 F and G Valves |
|
|
|
|
|
ML6161B1000 | Damper Actuator Series 60 | — |
|
|
|
|
|
M6410A | Valve Actuator Series 60 | Use with V5812/V5813 Valves |
|
|
|
|
|
ML684A1025 | Versadrive Valve Actuator with linkage, Series 60 | Use with V5011 and V5013 Valves |
|
|
|
|
|
ML6464A1009 | Direct Coupled Actuator, 66 | — |
|
|
|
|
|
|
| (continued) |
|