Fuser power supply
CAUTION: ESD sensitive.
Before proceeding, remove the following components:
●Left cover. See Left cover on page 17.
Remove the fuser power supply
1.Disconnect four connectors (callout 1)
Figure
1
2.Remove three screws (callout 1), and then remove the fuser power supply. Figure
1
42 Chapter 1 Removal and replacement | ENWW |