Upgrading Firmware through the Serial Port

20.Press Ctrl+_ twelve times in sequence to re-enable the escape character. The following text is displayed:

-----------------------------------------------------------------

Command: D)isconnect, C)hange settings, R)eboot Switch, E)xit command mode

-----------------------------------------------------------------

21.Press D to disconnect your session. If you changed the speed previously, you must reset your terminal to 9600 baud to continue. The following text is displayed:

-----------------------------------------------------------------

Command: D)isconnect, C)hange settings, R)eboot Switch, E)xit command mode > D

The console speed is being set back to 9600 bps.

Change your local speed back to 9600 and press [Enter] to continue

-----------------------------------------------------------------

22.Press Enter to close your connection to the switch module.

F-8

HP ProLiant BL e-Class C-GbE Interconnect Switch User Guide