RS-232C Port Specifications
PC control of the TV
When a program is set, the TV can be controlled from the PC using the
n
This operation system should be used by a person who is accustomed to using PCs.
Communication conditions
Set the
The TV’s communications settings are as follows:
Baud rate: | 9,600 bps |
|
|
Data length: | 8 bits |
|
|
Parity bit: | None |
|
|
Stop bit: | 1 bit |
|
|
Flow control: | None |
|
|
Communication procedure
Send the control commands from the PC with the
Command format
Eight ASCII codes + CR
| C1 | C2 | C3 | C4 | P1 | P2 | P3 | P4 |
|
|
|
|
|
|
| ||||||||||
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
| ||
Command |
|
| Parameter |
| Return code | |||||||
|
|
|
|
|
|
|
|
|
|
Command
Parameter
Parameter
Input the parameter values, aligning left, and fill with blank(s) for the remainder. (Be sure that 4 values are input for the parameter.) When the input parameter is not within an adjustable range, ERR returns. (Refer to “Response code format.”) Any numerical value can replace the x on the table.
0
0 | 0 | 0 | 9 |
|
|
|
|
|
|
|
|
2 | 3 | 0 |
|
|
|
|
|
|
|
|
|
1 | 0 | 0 |
|
|
|
|
|
|
|
|
|
0 | 0 | 5 | 5 |
|
|
|
|
When ? is input for some commands, the present setting value responds.
?
? | ? | ? | ? |
|
|
|
|
Response code format
Normal response
OK
Return code (0DH)
Problem response (communication error or incorrect command)
E R R
Return code (0DH)