List Views
If you have a
To change the poll settings for an individual node:
1.In the Method text box, use the down arrow to display a list of selectable polling options: None, Ping, SNMP MIB I, or SNMP MIB II. Drag down to select the desired option, and release.
2.In the Interval text box, enter the amount of time (in seconds) you want NetSight Element Manager to wait between polls to the interface. The valid range is 5 to 9999 seconds.
3.In the Retries field, enter the number of unsuccessful polls that must occur before NetSight Element Manager changes the node status to critical and logs an event. The valid range is 0 to 100.
4.Click Apply (if available) to save your changes and leave the Properties window open; or click OK to save your changes and close the window.
Three additional values may appear in the Method field, although they are not selectable options:
DLM Agent | If the selected device has been configured to be a DLM Agent, |
| the default polled interface will display a Method value of |
| DLM Agent, and the polling method will not be editable for |
| that interface. |
DLM Client | If the selected device has been configured as a DLM Client and |
| its assigned DLM Agent is functioning correctly, the default |
| polled interface will display a Method value of DLM Client, |
| and the polling method will not be editable for that interface. |
DLM Client (Direct) | If the selected device has been configured as a DLM Client and |
| its assigned DLM Agent is malfunctioning, the default polled |
| interface will display a method value of DLM Client (Direct), |
| indicating that NetSight Element Manager has taken over |
| polling of the device until the DLM Agent’s malfunction is |
| corrected. Again, the polling method will not be editable for |
| that interface. |
For more information about DLM and configuring status groups, see the DLM chapter in the NetSight Element Manager Tools Guide.
Adding Network Elements to the Node Database |