Overview of NetSight Element Manager

To change the interval (if desired):

1.Click in the Interval (sec) text field, and type in the poll interval to be used as a default when adding new devices. The range is from 5 to 9,999 seconds.

Retries

If individual device polling is in effect, this will determine the default number of times after a failed poll that NetSight Element Manager will re-poll a device before declaring it in a Critical (contact unavailable) state. To change the default Retries setting:

1.Click in the Retries text field, and type in the number of polls which will be issued to an individual device before declaring a contact unavailable status. The range is from 0 to 100 retries; the default is 3 retries.

Timeout (sec)

This field determines the default duration between retry polls to an individual device. To change the Timeout value:

1.Click in the Timeout (sec) text field, and type in the duration (in seconds) between re-polls after the initial poll failure. The range is from 1 to 90 seconds; the default is 4 seconds.

NOTE

This Timeout value can only be configured here, for all nodes; individual Node Properties windows do not provide the option of setting this value.

Directories Options

The Directories page lists the default locations used by NetSight Element Manager and its components to store and retrieve files. It also allows you to change the default Map and Export directories.

Customizing NetSight Element Manager

2-21

Page 37
Image 37
HP Netsight manual Retries, Timeout sec, Directories Options