8-8 IBM Informix OnLine Database Server Administrator’s Guide
Alphabetized Messages
Cannot execute gtrid_aaaa -- No TP monitor available.
(Thismessage is only received by users of the IBM Informix TP/XA product.)
AnOnLine database server process is making an XA function call within an
X/Openenvironment, but cannot detect the presence of a TP monitor. Refer
to the IBMInformix TP/XA User Manual.
Cannot Open Dbspace nnn
OnLine is unable to access the specified dbspace. This message indicates a
problem opening the tblspace tblspace or corruption in the initial chunk of
theroot dbspace. Verify that the root dbspace device is running properlyand
has the correctUNIX permissions (rw-rw----). You might be required to
perform a data restore.
Cannot Open Logical Log
OnLine is unable to access the logical log files. Since OnLine cannot operate
without access to the logical log, you must resolve this problem. Verify that
the chunk device where the logical log files reside is running properly and
has the correctUNIX permissions (rw-rw----). You might be required to
perform a data restore.
Cannot Open Mirror Chunk pathname errorno = nn
Themirror chunk of a mirrored pair cannot be opened. The chunk pathname
and the UNIX error are returned. Refer to your operating system documen-
tation for more information about corrective actions.
Cannot Open Primary Chunk pathname errorno = nnn
The primary chunk of a mirrored pair cannot be opened. The chunk
pathname and the UNIX error are returned. Refer to your operating system
documentation for more information about corrective actions.
Cannot Open Primary Chunk chunkname
The initial chunk of the dbspace cannot be opened. Verify that the chunk
deviceis running properly and has the correct UNIX permissions (rw-rw----).