108 IBM Tivoli Remote C ontrol Across Firewalls
3.3.3 Firewall configuration table

This section describes the correlation between the firewall customization and the

Tivoli environment to be implemented, providing the information a firewall

administrator should need in order to configure the ports properly on the firewall

to make the remote control session working, for this particular sc enario.

Table3-3 shows the c omponents that will communicate through the firewall and

the ports they use in our scenario.

Table 3-3 Scenario firewall configuration table

The schema provided in the previous table would allow for a data flow shown in

Figure3-4.

Figure 3-4 Remote Control Data Flow Overview

Source Destination Service/
Protocol
Description/
Activity
Component Port Component Port
Target Proxy 4000-4001
(1)
Controller
Proxy
30008 rcproxy/
TCP
rcproxy service
used to connect to
the Controller Proxy
Controller
Proxy
30008 Target Proxy 4000-4001
(1)
rcproxy/
TCP
rcproxy service
response to the
Target service
(1) Defined by the local-port-range parameter, as described in the Example3-7, the Port field should be in
the range (4000-4001).
Firewall
RC Controller Proxy
- child -
Remote Cont rol
Controller
RC Target Proxy
- parent -
- unidirectional -
Target
Endpoint
1
Random 8888 2
4000
4001
30008 3
Random 2501