Chapter 4. Implementation scenario: Tivoli Firewall Security Toolbox 127
For additional information related to the Remote Control Proxy installation you
can refer to the
IBM Tivoli Remote Control Users Guide
, SC23-4842.
Relay instance used by Remote Control
In our testing scenario we have to install a second instance of the Relay to be
used that will bridge the RC Target and Controller Proxies. The installation of the
Relay component is started by the TivoliRelay.exe command provided by the
Tivoli Firewall Security Toolbox 1.3 included in the IBM Tivoli Management
Framework 4.1media. On Windows 2000 Advanced Server, issue the following
command:
<CD-ROM>\tier1\new1\FST\Relay\w32-ix86\TivoliRelay.exe
Table4-6 shows the configuration settings we used in our lab for this scenario
during the Relay installation.
Table 4-6 Relay instance installation settings
Parameter Description Our settings
Relay port Port used by the Relay to
communicate with the Parent
7020
Relay or Endpoint
Proxy hostname
Hostname of Endpoint Proxy or
Parent Relay
tic01003
Relay or Endpoint
Proxy port
Port number of the Parent Relay or
Endpoint Proxy which this Relay will
communicate (*)
6020 (*)
Connection type Connection direction between the
Relay and its Parent
unidirectional
Unidirectional role in
relation to the RC
Target Proxy
Role of Relay when connection is
unidirectional:
- Initiator (client)
- Listener (server)
listener
Relay-port (Children
session)
Port used by the Relay to
communicate with it s Child
7021
Relay or Gateway
Proxy
The hostname of the Relay or
Gateway Proxy machine where this
Relay connects to
tic01005
Relay or Gateway
Proxy port
Port of the machine where this Relay
connects to
8020
Connection type Connection direction between the
Relay and its Child
unidirectional