126 IBM Tivoli Remote C ontrol Across Firewalls
RC Target Proxy installation
In our testing scenario the RC Target Proxy component should be installed on
Windows 2000 Server operating system. The installation is performed using the
Install Shield mechanism running the setup.exe command from the IBM Tivoli
Remote Control 3.8 media as follows:
<CD-ROM drive>\new\RCPROXY\w32-ix86\setup.exe
As soon as the installation process starts, it automatically detects the TFST code
already installed on the machine. Since this installation detects an Endpoint
Proxy installation, the RC Target Proxy will be automatically configured as a
Parent Proxy.
Table4-5 shows the configuration settings we used in our lab for this scenario
during the RC Target Proxy installation.
Table 4-5 RC Target Proxy installation settings
Parameter Description Our settings
Local port Port used locally by the Parent Proxy
to listen from its Children (* )
6020 (*)
Network interface Hostname of Child Proxy or RC
Controller Proxy listening for
connection
tic01004
Port number used by
Child Proxy
Remote port used by Child Proxy or
RC Controller Proxy to listen for
connections
7020
Connection type Connection direction between the
Parent Proxy and its Children
unidirectional
Unidirectional role Role of Parent Proxy when
connection is unidirectional:
- Initiator (client)
- Listener (server)
initiator
Proxy type Role of the Parent RC Proxy Target
Port number Port on which this Proxy listens for
connection from Controllers and RC
Controller Proxy (must match with
value in rc_def_proxy policy)
5020
Command line port Command line port on which this
Proxy listens for request (used by the
rcproxy command)
3333
(*) This parameter is mandatory during the installation. Since the connection type is
unidirectional and the RC Target Proxy is configured as initiator, port 6020 will never be
used.