126 IBM Tivoli Remote C ontrol Across Firewalls
RC Target Proxy installationIn our testing scenario the RC Target Proxy component should be installed on 
Windows 2000 Server operating system. The installation is performed using the 
Install Shield mechanism running the setup.exe command from the IBM Tivoli 
Remote Control 3.8 media as follows:
<CD-ROM drive>\new\RCPROXY\w32-ix86\setup.exe
As soon as the installation process starts, it automatically detects the TFST code 
already installed on the machine. Since this installation detects an Endpoint 
Proxy installation, the RC Target Proxy will be automatically configured as a 
Parent Proxy.
Table4-5 shows the configuration settings we used in our lab for this scenario 
during the RC Target Proxy installation.
Table 4-5   RC Target Proxy installation settings
Parameter Description Our settings
Local port  Port used locally by the Parent Proxy 
to listen from its Children (* )
6020 (*)
Network interface  Hostname of Child Proxy or RC 
Controller Proxy listening for 
connection
tic01004
Port number used by 
Child Proxy
Remote port used by Child Proxy or 
RC Controller Proxy to listen for 
connections
7020
Connection type Connection direction between the 
Parent Proxy and its Children
unidirectional
Unidirectional role Role of Parent Proxy when 
connection is unidirectional:
- Initiator (client)
- Listener (server)
initiator
Proxy type Role of the Parent RC Proxy Target
Port number  Port on which this Proxy listens for 
connection from Controllers and RC 
Controller Proxy (must match with 
value in rc_def_proxy policy) 
5020
Command line port Command line port on which this 
Proxy listens for request (used by the 
rcproxy command) 
3333
(*) This parameter is mandatory during the installation. Since the connection type is 
unidirectional and the RC Target Proxy is configured as initiator, port 6020 will never be 
used.