from connecting block

Operating components not reached by the remote controller signals (IR IN/OUT)

The following equipment (sold separately) is essential for operation:

Onkyo’s Multi-Room System kits (IR Remote Controller Extension System), or

Multiroom A/V distribution and control systems from Niles® and Xantech® to name a few

Make connection as shown below. Do not plug the equipment into the power source until the connection is complete.

from connecting block

Mini plug cable other component

If the remote controller signal does not reach the DTR-6.2 remote sensor

If the DTR-6.2 is located inside a cabinet or other enclosure where the infrared rays from the remote controller cannnot enter, then operation with the remote controller will noe be possible. In such a case, it will be necessary to install a remote sensor at a location outside of the cabinet for the infrared rays from the controller to reach.

With this connection, select “Main” for the Preference IR IN Setup Position setting in the Setup menu (see page 42).

IR

IN

OUT

DTR-6.2

If the remote controller signal does not reach other components

IR IN

DTR-6.2

Connecting

IR Receiver

block

 

In this situation, you will need to use a commercially available IR emitter. Connect the mini plug of the IR emitter to the IR OUT terminal on the DTR-6.2 and then place the IR emitter on the remote sensor of the component or facing it. When the IR emitter is connected, only the signal input to the IR IN terminal is output to the IR OUT terminal. The signal input from the remote sensor on the front of the DTR-6.2 will not be output to the IR OUT terminal.

In the cobinet

Remote Controller

Connecting block

IR IN

IR Receiver

Manual background DTR-6.2

Manual background : Signal flow

The IR IN input allows you to control the DTR-6.2 from the remote zone (Zone 2) with the remote controller even though the remote zone is physically separated. The diagram below shows how to make the proper connections for the remote zone.

With this connection, select “Zone 2” for the Preference IR IN Setup Position setting in the Setup menu (see page 42).

To IR IN

IR Receiver

DTR-6.2

Connecting block

Remote controller

Main room

Remote room

Manual background : Signal flow

IR OUT

IR Emitter

Remote Controller

other component

Manual background : Signal flow

other component

Manual background : Signal flow

Manual backgroundManual background Remote control sensor

IR

 

Emitter

IN

 

OUT

Mini plug

Mini plug cable

 

DTR-6.2

IR Emitter

 

20

Page 20
Image 20
Integra DTR-6.2 instruction manual from connecting block, other component