Intel® 31244 PCI-X to Serial ATA Controller
Thermal Solutions
Thermal Solutions | 15 |
GD31244 is packaged in a 17 mm,
Table 37. | Thermal Resistance |
|
| |
|
|
|
|
|
| Symbol | Description | Value | Units |
|
|
|
|
|
| T | Still air ambient temperature to meet maximum case temperature | 70 | oC |
| A | specifications: [TA = TC - |
|
|
|
|
|
| |
| θ | Thermal resistance from case to ambient in still air including | 20 | oC/Watt |
| ca | conduction through the leads |
|
|
|
|
|
|
|
Table 38. |
|
|
|
|
| |||
|
|
|
|
|
|
|
| |
|
| Thermal Resistance - oC/Watt |
|
|
| |||
|
|
|
|
|
|
|
|
|
| Parameter |
|
|
| Airflow - ft/min. (M./sec.) |
| ||
|
|
|
|
|
|
|
| |
|
|
| 0 |
| 100 | 200 | 400 | 600 |
|
|
|
|
|
|
|
|
|
| θca |
| 20 |
| 12.5 | 11.2 | 10.2 | 9.2 |
| Thermal Resistance from case to Ambient |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
15.1Thermal Recommendations
Based on data Intel gathered while performing thermal validation, the GD31244 does not require a heat sink. The tests were performed in an environment with no airflow, an ambient temperature of 60° C with the processor executing a maximum power test. However, when the case temperature (108° C) is exceeded, a passive heat sink may be used.
Design Guide | 77 |