STL2 Server Board TPS

Server Management

 

 

 

 

 

 

 

Sensor Number

Sensor Type

Monitoring Device

 

 

 

 

 

 

 

94h

BIOS POST (Error) Code

 

 

 

 

 

 

 

 

95h

Log Disable

Log Area Reset / Cleared (bit 2)

 

 

 

 

ECC single bit Error Disable (bit 0)

 

 

 

 

 

 

 

96h

System Event

OEM System Event (Hard Reset) (bit 1) System

 

 

 

 

 

 

 

97h

Critical Interrupt

PCI SERR (bit 5)

 

 

 

 

PCI PERR (bit 4)

 

 

 

 

Front Panel NMI (Dump SW) (bit 0)

 

 

 

 

 

 

 

98h

Button

Reset Button (bit 2)

 

 

 

 

Sleep Button (bit 1)

 

 

 

 

Power Button (bit 0)

 

 

 

 

 

 

 

99h

No Processor or Termination Board

 

 

 

 

 

 

 

 

9Ah

Boot Init

User requested PXE boot (bit 3)

 

 

 

 

Initiated by power up (bit 0)

 

 

 

 

 

 

 

9Bh

Boot Error

PXE Server not found (bit 2)

 

 

 

 

No bootable media (bit 0)

 

 

 

 

 

 

 

9Ch

OS Boot

 

 

 

 

 

 

 

 

9Dh

OS Stop

 

 

 

 

 

 

 

 

9Eh

ACPI State

Sleeping in S1 state (bit 8)

 

 

 

 

G3/Mechanical Off (bit 7)

 

 

 

 

S5 / G2 Soft Off (bit 5)

 

 

 

 

S4 (bit 4)

 

 

 

 

 

 

 

A0h

BMC Watchdog

BMC WDT Timeout

 

 

 

 

 

 

 

C0h

Chassis Intrusion ID (Disable)

Processor Area Intrusion (bit 4)

 

 

 

 

 

 

 

C1h

Chassis Intrusion ID

Drive Bay Intrusion (bit 1)

 

 

 

 

 

 

 

F3h

SMI State

SMI Stall State

 

 

 

 

 

 

The following table provides a list of System Event Log (SEL) events supported by the STL2 server board.

Sensor Type

Sensor Type

Sensor-Specific

Event

Remarks

 

Code

Offset

 

 

 

 

 

 

 

Reserved

00h

Reserved

 

 

 

 

 

 

Temperature

01h

Temperature

An error occurred at thermal sensors

 

 

 

 

 

Voltage

02h

Voltage

An error occurred at voltage sensors

 

 

 

 

 

 

 

01h

Performance Lags

In the single-end event mode, even if

 

 

 

 

SCSI is available for a different

 

 

 

 

mode event.

 

 

 

 

 

Fan

04h

Fan

An error occurred at fan sensors.

 

 

 

 

 

Physical Security

05h

01h

Drive Bay Intrusion

Front cover has been opened or

 

 

 

 

closed

 

 

 

 

 

 

 

03h

Processor area intrusion

Side (Chassis) cover has been

 

 

 

 

opened or closed.

 

 

 

 

 

 

 

04h

LAN Connection Lost

 

 

 

 

 

 

(System has been

LAN cable has

 

 

 

unplugged from LAN)

been plugged

 

 

 

 

in or

 

 

 

 

unplugged.

 

 

 

 

 

 

 

 

Revision 1.0

3-25

Page 33
Image 33
Intel STL2 manual Sensor Type Sensor-Specific Event Remarks Code Offset

STL2 specifications

The Intel STL2, known as the Intel Storage Technology Level 2, is a robust solution designed to elevate storage management and performance for enterprise-level applications. This next-generation system is specifically tailored for organizations that demand high reliability, scalability, and efficiency in their storage solutions.

One of the primary features of the Intel STL2 is its advanced data protection mechanisms. With integrated RAID (Redundant Array of Independent Disks) support, it ensures that data remains safe, even in the event of hardware failure. RAID configurations can be easily set up and managed, allowing businesses to choose the right balance between performance and redundancy based on their unique requirements.

In terms of performance, the STL2 leverages cutting-edge SSD (Solid State Drive) integration to provide high-speed data access and reduced latency. This capability is essential for modern applications that require quick retrieval of large volumes of data, making it suitable for environments like data analytics, AI, and cloud computing.

Scalability is another significant characteristic of the Intel STL2. It is designed to grow alongside an organization’s needs, supporting a diverse range of storage architectures. Whether a company is looking to expand its data center or transition to hybrid cloud solutions, the STL2 can accommodate additional storage resources effortlessly, ensuring that performance does not degrade as storage demands increase.

Moreover, the STL2 features advanced automation and management tools that simplify storage operations. The system allows for real-time monitoring and analytics, providing insights into storage health, performance metrics, and capacity forecasts. This level of visibility enables IT teams to optimize resource utilization and proactively address potential issues before they become critical.

Another notable technology integrated into the STL2 is Intel’s Open Storage Architecture, which promotes interoperability with various software and hardware platforms. This open approach facilitates seamless integrations with existing systems and enhances flexibility within dynamic IT environments.

Lastly, Intel STL2 prioritizes energy efficiency. Its design minimizes power consumption without sacrificing performance, helping organizations reduce their operational costs and carbon footprint.

In summary, the Intel STL2 stands out in the competitive landscape of storage solutions with its focus on data protection, high performance, scalability, advanced management features, open architecture compatibility, and energy efficiency. These characteristics make it an ideal choice for businesses looking to enhance their data storage capabilities in a rapidly evolving digital landscape.