Page 25

TM-4200GE Software

Input

Signal

Description

Label

 

 

 

 

 

I5

CTRL0

Internal control signal.

 

 

PULSE_GEN2

Pulse Generator 2 signals go here.

 

 

 

 

I6

PULSE_GEN1

Pulse Generator 1 signals go here.

 

 

N/A

 

 

 

 

 

 

I7

PULSE_GEN0

Pulse Generator 0 signals go here.

 

 

N/A

 

 

 

 

 

 

Table 3 shows which output labels carry the output signals.

TABLE 3. GPIO Look-Up Table Output Labels

Output label

Signal

Description

 

 

 

Q0

TTL-OUT(STROBE)

Strobe output

 

 

 

Q1

N/A

 

 

 

 

Q2

N/A

 

 

 

 

Q3

N/A

 

 

 

 

Q4

EVINIT

Trigger

 

 

 

Q5

INTG_CON

Integration control

 

 

 

Q6

EXT_VD

Vertical Drive

 

 

 

Q7

EXT_HD

Horizontal Drive

 

 

 

Q8

pulse_trig1

Pulse Generator 1 gets its trigger here

 

 

 

Q9

pulse_trig0

Pulse Generator 0 gets its trigger here

 

 

 

Q10

pulse_trig3

Pulse Generator 3 gets its trigger here

 

 

 

Q11

pulse_trig2

Pulse Generator 2 gets its trigger here

 

 

 

Q12

N/A

 

 

 

 

Q13

N/A

 

 

 

 

Q14

TRIG

Trigger for camera’s internal frame grabber

 

 

 

Q15

RESV

Reserved

 

 

 

4.5 Pulse Generators

The TM-4200GE camera has four independently programmable pulse generators. These generators can run as either periodic or triggered. To run the pulse generators as triggered, they can be triggered on either levels or signal edges. These generators can be tied to the camera inputs (camera-control lines). For example, you can set pulse generator 0 in the Device Features tabbed dialog box to the following values:

Delay = 600

Width = 14,000