Page 25

TM-4200GE Software
Signal Handling
Table3 shows which output labels carry the output signals.
TABLE 3. GPIO Look-Up Table Output Labels
4.5 Pulse Generators
The TM-4200GE camera has four independently programmable pulse generators. These generators can
run as either periodic or triggered. To run the pulse generators as triggered, they can be triggered on
either levels or signal edges. These generators can be tied to the camera inputs (camera-control lines).
For example, you can set pulse generator 0 in the Device Features tabbed dialog box to the following
values:
Delay = 600
Width = 14,000
I5 CTRL0 Internal control signal.
PULSE_GEN2 Pulse Generator 2 signals go here.
I6 PULSE_GEN1 Pulse Generator 1 signals go here.
N/A
I7 PULSE_GEN0 Pulse Generator 0 signals go here.
N/A
Output label Signal Description
Q0 TTL-OUT(STROBE) Strobe output
Q1 N/A
Q2 N/A
Q3 N/A
Q4 EVINIT Trigger
Q5 INTG_CON Integration control
Q6 EXT_VD Vertical Drive
Q7 EXT_HD Horizontal Drive
Q8 p ulse_trig1 Pulse Generator 1 gets its trigg er here
Q9 p ulse_trig0 Pulse Generator 0 gets its trigg er here
Q10 pulse_trig3 Pulse Generato r 3 gets its trigger here
Q11 pulse_trig2 Pulse Generator 2 gets its trigger here
Q12 N/A
Q13 N/A
Q14 TRIG Trigger for camera’s internal frame grabber
Q15 RESV Reserved
Input
Label Signal Description