Page 29

 

 

 

 

 

 

 

 

 

 

 

 

 

TM-4200GE Software

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command

 

Parameter

End of

 

Ack. Response

Description

 

 

 

 

 

 

Cmd

 

 

 

 

 

 

Miscellaneous

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:DUL=

 

X

<cr>

 

:o<cr>

 

Single Tap/Dual Tap Selection (X = 0

 

 

 

 

 

 

 

 

 

 

 

 

 

Dual Tap, X = 1 Single Tap)

 

 

 

:DDP=

 

X

<cr>

 

:o<cr>

 

Set Output Data Depth (X = 0 8-bit, X =

 

 

 

 

 

 

 

 

 

 

 

 

 

1 10-bit, x = 2 12-bit)

 

 

 

:CCS=

 

X

<cr>

 

:o<cr>

 

Select Camera Control signals (X = 0 CL

 

 

 

 

 

 

 

 

 

 

 

 

 

Conn, X = 1 Hirose Conn)

 

 

 

:TAH=

 

X

<cr>

 

:o<cr>

 

External Trigger Polarity (X = 1 Active

 

 

 

 

 

 

 

 

 

 

 

 

 

High, X = 0 Active Low)

 

 

 

:TPTN

 

X

<cr>

 

:o<cr>

 

Enable/Disable Test Pattern (X = 1

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable, X = 0 Disable)

 

 

 

:CAM?

 

 

 

<cr>

 

:o[model]<cr>

Inquire Camera Model

 

 

 

 

:VER?

 

 

 

<cr>

 

:o[version]<cr>

Inquire MPU firmware version

 

 

 

 

:SGE=

 

X

<cr>

 

:o<cr>

 

Set Digital Output Interface

 

 

 

 

 

 

 

 

 

 

 

 

 

(X = 0 CameraLink, X = 1 GigE)

 

 

 

:CCD=

 

X

<cr>

 

:o<cr>

 

CCD information (X = 1)

 

 

 

 

:PuLX

 

X

<cr>

 

:o<cr>

 

Password (X = 1 Administrator, X = 0

 

 

 

 

 

 

 

 

 

 

 

 

 

Users)

 

 

 

 

 

 

Note: If a command is not accepted for any reason, the camera will return a “nack” response. “:e”

 

 

 

<cr> *Not available yet.

 

 

 

 

 

 

 

 

 

 

 

 

TABLE 5. Command Responses

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Command

 

Parameter

 

End of Cmd

Description

 

 

 

 

 

 

Byte 1, 2

 

Master Gain

 

 

 

 

Master Gain (H'0000 - H'0FFF: -3dB - +12dB)

 

 

 

 

 

 

 

R Channel

 

 

 

 

 

 

 

 

 

 

 

 

Byte 3, 4

 

Fine Gain

 

 

 

 

R Channel Fine Gain (H'0000 - H'0FFF)

 

 

 

Byte 5, 6

 

Master Offset

 

 

 

 

Master Offset (H'0000 - H'0FFF)

 

 

 

 

 

 

 

R Channel

 

 

 

 

 

 

 

 

 

 

 

 

Byte 7, 8

 

Fine Offset

 

 

 

 

R Channel Fine Offset (H'0000 - H'0FFF)

 

 

 

Command

 

Parameter

 

End of Cmd

Description

 

 

 

 

 

 

 

 

 

Function Flag

 

 

 

 

 

 

 

 

 

 

 

 

Byte 9

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0000=2048x2048

0001=2048x1000

 

 

 

 

 

 

 

Bit 0

 

Scan Area 0

0010=2048x500

0011=2048x250

 

 

 

 

 

 

 

 

 

 

 

0100=2x2 binning of 2048x2048

 

 

 

 

 

 

 

Bit 1

 

Scan Area 1

1111=User Programmable Scan Area

 

 

 

 

 

 

 

 

 

 

 

1000=Digital Zoom x1

1001=Digital Zoom

 

 

 

 

 

 

 

Bit 2

 

Scan Area 2

x2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1000=Digital Zoom x3

1001=Digital Zoom

 

 

 

 

 

 

 

Bit 3

 

Scan Area 3

x4

 

 

 

 

 

 

 

 

 

 

Bit 4

 

Rsvd

 

 

 

 

 

 

 

 

 

 

 

 

Bit 5

 

Rsvd

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pixel Output

 

 

 

 

 

 

 

 

 

 

 

Bit 6

 

Order 0

 

00=<---<--- 01<=<------>

 

 

 

 

 

 

 

 

 

Pixel Output

 

 

 

 

 

 

 

 

 

 

 

Bit 7

 

Order 1

 

10=<<------

 

 

 

 

 

 

 

 

 

Function Flag

 

 

 

 

 

 

 

 

 

 

 

 

Byte 10

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Continuous Mode: 0000 - 1001=Continuous

 

 

 

 

 

 

 

Bit 0

 

Shutter 0

preset shutter 0 - 9

 

 

 

 

 

 

 

 

Bit 1

 

Shutter 1

Trigger Mode:

 

 

 

 

GigE Series Camera Serial Commands

Page 41
Image 41