TM-4200GE Software

 

 

 

0000=Async no shutter 0001 - 1000=Async

 

Bit 2

Shutter 2

preset shutters 1-8

 

 

 

1001=PWC

1010=PIV Fixed Exposure

 

Bit 3

Shutter 3

1011=PIV PWC

 

 

 

 

00=Continuous Preset Shutter 01=Trigger

 

Bit 4

Shutter Mode 0

Preset Shutter

 

 

 

 

10=Trigger Programmable Shutter

 

Bit 5

Shutter Mode 1

11=Continuous Programmable Shutter

 

Bit 6

Data Depth 0

00=8bit 01=10bit

 

Bit 7

Data Depth 1

10=12bit

 

 

 

Function Flag

 

 

 

 

Byte 11

2

 

 

 

 

 

Bit 0

Look-up table 0

00=Linear

01=Gamma.45

 

Bit 1

Look-up table 1

10=User Knee Table

 

Bit 2

Rsvd

 

 

 

 

 

Camera Control

0=CameraLink Connector 1=Hirose 12pin

 

Bit 3

Signals

Connector

 

 

 

Bit 4

Rsvd

 

 

 

 

 

Trigger Signal

 

 

 

 

Bit 5

Polarity

0=Active Low

1=Active High

 

 

Dual / Signal

 

 

 

 

Bit 6

Tap

0=Dual Tap

 

1=Single Tap

 

 

Positive /

 

 

 

 

Bit 7

Negative LUT

0=Positive LUT

1=Negative LUT

 

Function Flag

 

 

 

 

Byte 12

3

 

 

 

 

 

 

R Channel Auto

 

 

 

 

Bit 0

Fine Gain

0=Disable

1=Enable

 

 

R Channel Auto

 

 

 

 

Bit 1

Fine Offset

0=Disable

1=Enable

 

Bit 2

Rsvd

 

 

 

 

Bit 3

Rsvd

 

 

 

Command

Parameter

End of Cmd

Description

 

 

 

 

Blemish

 

 

 

 

Bit 4

Compensation

0=Disable

1=Enable

 

Bit 5

Rsvd

 

 

 

 

Bit 6

Password

0=Disable

1=Enable

 

Bit 7

Test Pattern

0=Disable

1=Enable

Byte 13, 14

(X1, Y1)

 

Coordinate for Knee 1 (X1, Y1=H'00 - H'FF)

Byte 15, 16

(X2, Y2)

 

Coordinate for Knee 2 (X2, Y2=H'00 - H'FF)

 

Start Line of

 

 

 

 

 

Programmable

 

Start Line of Programmable Scan Area

Byte 17, 18

Scan Area

 

(H'0000 - H'07FF)

 

Total Lines of

 

 

 

 

 

Programmable

 

Total Lines of Programmable Scan Area

Byte 19, 20

Scan Area

 

(H'0001 - H'0800)

 

Shutter Speed

 

 

 

 

 

of

 

 

 

 

 

Programmable

 

Shutter Speed of Programmable Shutter

Byte 21, 22

Shutter

 

(H'0000 - H'081F)

Byte 23, 24

Vsub Voltage

 

Vsub Voltage (H'0600 - H'0D00=7.8V - 17V)

GigE Series Camera Serial Commands

Page 42
Image 42
JAI TMC-4200GE operation manual 0000=Async no shutter 0001 1000=Async