Page 70

TM-4200GE Hardware

9.5 External Sync and Pixel Locking

The TM-4200CL accepts an external sync of standard HD and VD at TTL level for general locking to a system sync and clock. The frequency requirement is as follows:

Full Progressive Scan:

fHD = 30.769 KHz ± 2% fVD = 14.79 Hz ± 2%

(Internal Master clock = 80.00 MHz, Pixel clock = 40.00 MHz)

100L Partial Scan:

fHD = 30.769 KHz ± 2%

fVD = 27.97 Hz ± 2%

500L Partial Scan:

fHD = 30.769 KHz ± 2%

fVD = 49.63 Hz ± 2%

250L Partial Scan:

fHD = 30.769 KHz ± 2%

fVD = 79.92 Hz ± 2%

9.6 Camera Timing Charts

FIGURE 70. Camera Timing Chart

Operation