Page 26

TM-4200GE Software

Granularity = 1

Now check the Periodic option and change the camera settings to Async 9. This triggers the camera, based on the pulse width set in the Pulse Generator page.

Be careful with the pulse generator’s GPIO input and output polarity. If the delay and pulse-width duration are switched around, the output polarity must be negated in the GPIO lookup table.

The pulse generators are configured in the Pulse Generator section of the Device Features tab of the Advanced Configuration window as shown in Figure 26.

FIGURE 26. Pulse Generator Page

Signal Handling

Page 38
Image 38
JAI TMC-4200GE operation manual Pulse Generator