6. Menu screen settings (continued)

EXPOSURE screen (continued)

 

Menu item

Function/variable range

Default value

SHUTTER

 

 

 

 

 

 

 

SPEED

The shutter sped can be changed when the shutter is set

STEP: 1/8 s

 

 

to STEP, V.SCAN or RANDOM.

V.SCAN:

 

 

[STEP variable range: 4 s, 2.8 s, 2 s, 1.4 s, 1 s, 1/2 s, 1/4 s,

1/30 s

 

 

1/8 s, 1/15 s, 1/30 s, 1/60 s, 1/125 s,

RANDOM:

 

 

1/250 s, 1/500 s, 1/1000 s, 1/2000 s]

1/125 s

 

 

[V.SCAN variable range: 1/30 s ~ 1/5906.8 s]

 

 

 

[RANDOM variable range: 1/8 s, 1/15 s, 1/30 s, 1/60 s, 1/125 s,

 

 

 

1/250 s, 1/500 s, 1/1000 s, 1/2000 s]

 

MEMO

When the shutter speed is slower than 1/4 s (1/15 s in the VGA DRAFT mode), the screen update rate becomes longer in correspondence with the shutter speed, and time will be required for the following operations.

Auto white, auto iris, ALC

If the shutter speed is set at 1.4 s or slower, these opera- tions behave as follows.

Auto white : Auto white balance function cannot be started. (  page 30 White balance adjustment)

Auto iris : Stops at the iris value at that time.

ALC : Stops at the sensitivity at that time.

To use a shutter speed of 1.4 s or slower, use with the following settings selected:

IRIS MODE :

MANUAL

SENSITIVITY :

STEP or V.SENS

There may be shortage of light when increasing the shut- ter speed. In this case, adjust the iris or sensitivity. Spe- cial attention is required for the picture quality when rais- ing the sensitivity since images may show artefacts.

SENSITIVITY

Used to set the sensitivity mode.

STEP

 

 

STEP:

the sensitivity can be changed by means of the

 

 

 

 

LEVEL submenu item.

 

 

 

ALC:

the sensitivity si automatically changed by the

 

 

 

 

ambient brightness. Maximum sensitivity is set

 

 

 

 

in the next ALC MAX menu item.

 

 

 

V.SENS: the sensitivity can be set in detail using the

 

 

 

 

LEVEL submenu item.

 

 

 

 

 

 

 

LEVEL

The sensitivity can be changed when the sensitivity mode

STEP:

 

 

is set to STEP or V.SENS.

ISO100

 

 

[STEP variable range: ISO100, ISO200, ISO400]

V. SENS:

 

 

[V.SENS variable range: ISO100 ~ ISO400]

ISO100

 

 

 

 

 

ALC MAX

This can be set when the sensitivity mode is set to ALC.

ISO400

 

 

Used to set the maximum sensitivity of ALC, which automati-

 

 

 

cally switches the sensitivity depending on the brightness.

 

 

 

[Variable range: ISO200, ISO400]

 