Menu Display and Detailed Settings

Others Menu (continued)

Genlock Adjust Item

* Default values are indicated in bold characters.

Item

Setting Values

Function

Analog SD H

Min, -27 to 0 to 81, Max

For adjusting the H phase of the SD analog signal of the camera recorder with respect to

Phase

 

the external synchronizing signal input to the [GENLOCK INPUT] terminal.

 

 

Increase value : Advances the H phase.

 

 

Decrease value : Delays the H phase.

 

 

Analog HD H

Min, -1023 to 0 to 1022, For adjusting the H phase of the HD analog signal of the camera recorder with respect to

Phase

Max

the external synchronizing signal input to the [GENLOCK INPUT] terminal.

 

 

Increase value : Advances the H phase.

 

 

Decrease value : Delays the H phase.

 

 

Memo:

 

 

 

 

 

 

 

 

When [System Definition] in the [Record Format] menu is set to ASD (DV)B, this item

 

 

 

appears as A---Band cannot be selected. (A Page 75)

 

 

 

 

 

 

 

 

 

SD-SDI H Phase

Min, -372 to -1, 0, 1 to

For adjusting the H phase of the SD-SDI signal of the camera recorder with respect to the

 

 

372, Max

external synchronizing signal input to the [GENLOCK INPUT] terminal.

 

 

 

Increase value : Advances the H phase.

 

 

 

Decrease value : Delays the H phase.

 

 

 

Memo:

 

 

 

 

 

 

 

 

When [HD/SD-SDI Out] in the [A/V Out] menu is set to a setting other than ASD (DV)B,

 

 

 

this item appears as A---Band cannot be selected. (A Page 92)

 

 

 

 

 

 

 

 

 

HD-SDI H Phase

Min, -1023 to 0 to 1022,

For adjusting the H phase of the HD-SDI signal of the camera recorder with respect to the

 

 

Max

external synchronizing signal input to the [GENLOCK INPUT] terminal.

 

 

 

Increase value : Advances the H phase.

 

 

 

Decrease value : Delays the H phase.

 

 

 

Memo:

 

 

 

 

 

 

 

 

When [HD/SD-SDI Out] in the [A/V Out] menu is set to a setting other than AHD-SDIB,

 

 

 

this item appears as A---Band cannot be selected. (A Page 92)

 

 

 

 

 

 

Memo :

You can alter the setting value in increments of 10 by pressing down the cross-shaped button (JK) for 2 seconds or longer. (Excluding the [Analog SD H Phase] item)

96