WA] ER SUPPLY

Plumbing must comply with local codes It is recommended that a shul-off valve be installed in the line from the supply to the dishwasher The water supply must be able lo supply a minimum of 9 quarts in one minute Route the Ime, as shown in Figure 7 (Refer to Figure 5 for permissible routing areas) Do not run it across in front of the motor Piping must not be kinked The connection to the valve is made with a 3/8" male pipe thread right angle adapter Assemble the adapter to the valve, using pipe compound or teflon tape, with a wrench on the adapler and a wrench over the metal bracket enclosing the fitting on the valve If solder connections are used. use care to see that valve is not overhea!ed CAUTION! Qverheating witl da0qage the valve Clean all ioreign matedal from the pipe and threads before maldng final connections

IMPORTANT:

TURN ON THE WATER SUPPLY AND CHECK ALL PLUMBING AIqD DISHWASHER CONNECTIONS FOR WATER LEAKS.

WARNING!

Do not have line pressure Io the water valve in freezing temperatures during construction, remodeling, elc Do not use the drain hose supplied with the dishwasher for the water supply line It is not a reinforced hose and will burst under water line pressure

CAUTION

I

To prevent damage to valve,apply wrench to hex on valvemetal bracket

and hold securely while installing rigflt angle adapter,,

SUPPLY

I I

_REEN GROUND" SCREW

ALTERNATE HOT WATER

ENTRY SHOWN BY

SHUT OFF VA LV E

DDT_ED LINE

\

HOT WATE

LINE

MOLDED REO EPTACL

/

RIGHT ANGLE ADAPTER -3/8

MALE PIPE THREAD

FIGURE7

12

Page 15
Image 15
Kenmore 808353 manual Reen Ground Screw, Shut OFF VA LV E, HOT Wate Line