ELECTRICAL

All wiring must be in accordance with electrical codes The dishwasher operates on !15 volt, 60 cycle power Pro- vide a separate circuit with a fuse or circuit breaker rated for at least 15 amps bul not more than 20 amps

GROUND1NGINSTRUCTIONS

This appliance must be connected to a grounded metal, permanent, wiring system; or an equipment grounding

conductor must be run with the circui_ conductors and connected to the equipment-grounding terminal A green ground screw terminal is provided in The junction box Connecting the circuit conductor ground, along with the molded receptacfe green pigtail, automatically grounds 1he dishwasher

install the wiring, routing it within the zones shown in Figure 5 Do not run i! across in front of the motor Connect lhe circuit black 1o the machine black, and circuil white to the machine white, using wire nuts If house wi_ing is

aluminum, a UL or CSA listed antioxidant compound must be used with listed aluminum-to-copper connectors

Connect the circuit conductor ground wire under the green ground screw Refer to Figure 6 Replace the junction box cover

CIRCUIT CONDUCTORGROUND WIRE

¢7IRING

GREEN GROUND

SCREW

\

FIGURE6

11

Page 14
Image 14
Kenmore 808353 manual Green Ground Screw, Electrical, GROUND1NGINSTRUCTIONS, Circuit Conductorground Wire