Wetting Agent Dispenser - Bi-Metal Operated
A completely redesigned supply tank and a
The door must be fully openedfor a few seconds to allow the wetting agent liquid to fill up in a scoop (Figure 50),
DOOR IN FULLY OPENED POStTI
FILL NECK
-SCOOP
WETTING AGENT LIQUID
FIGURE50
When the door is closed the wetting agent liquid in the scoop then fills the area at the bottom portion'bf the inner valve stopper and any extra !iquid drains back into the supply tank (Figure 51 ),,
PLUNGER_._
RESERVOIR FILLS
WITH LtOUID FROM
POSITION
' _DOOR IN CLOSED
ZXC_S LtOUIO
DRAINSBACK .J _NTOSUPP_._" I
AL
ENERGIZED BIMET LIFTS PLUNGER
INTO FILL NECK
FILL, NEC_ _
FIGURE51
FIGURE52
Thiscontrolledamount ofwettingagentliquidatthelowersectionof thestopperisreleasedintothefillneckduring thewaterfillofthe4th (last)rinseonly.(Figure52)
To check for proper operation, with wetting agent liquid in the supply tank, start the dishwasher in the normal manner, then manually advance the timer to the fill of the last rinse, The
shortlyafterthisfiJl,The wetting agent willthen flow from the valvearea out to fillneck for mixing with the rinse water_
47