Thermostats and Temperature Indicators

ASam-Wash or High Temperature Wash/Rin.se Thermostat

Most dishwashers are equipped with a thermostat to provide for guaranteed hot water in the 2nd Wash and/or Final Rinse when a Sani-Wash or high temperature wash is selected.. Unless the water temperature is high enough to satisfy the thermostat, the thermostat stops the timer until the heater in the machine raises the water temperature enough to satisfy the thermostat

If the water temperature in the tub is below the thermostat setting the switch remains open and the timer motor does not run, prolonging the rinse cycle until the water temperature rises to the thermostat setting When this temperature is reached, the bimetal strip within the thermostat deflects and doses the contacts (dosing the circuit to the time_- m6tor) and the timer resumes operation to complete the dishwashing cycle; See Figure 58

--THERMOSTAT INSTALLED

"MYLAR JACKET

CROSS SECTION OF THERMOSTAT

FIGURE58

The heater in the machine will raise the water temperature approximately one degree per minute Thus, if the water is 135 degrees at the start of the Second Wash or Fourth Rinse and the thermostat is calibrated to 150 degrees, the timer will stop for approximately 15 minutes in the Second Wash or Fourth Rinse (or both) while the water is being heated, During the time that the thermostat is calling for'heat, there is no power to the timer motor although the wash system continues to function

Depending on the model dishwasher, the thermostat may be calibrated at 140° to 150 ° Some Lady Kenmore models contained 2 thermostats; one which is a round disk type, and the other which is of a tubular design The

disk type is calibrated for t50 °, and the tubular type is calibrated for 1200

B_ Checking Thermostat Operation

If the second wash or final rinse cycle is not delayed (when a Sani-Cyde has been selected), despite a temperature of less than 130° F in the tub:

1, Check for incorrect wiring (use schematic).

2, Check for a defective thermostat Contacts should be open when cold,

3.Check for short in thermostat circuit.

4Check for too low a calibration of the thermostat, Thermostat calibration may be determined by measuring the temperature of the water expelled from the machine following a thermostatic delay

5t

Page 54
Image 54
Kenmore 808353 manual Thermostats and Temperature Indicators, Mylar Jacket, Checking Thermostat Operation