E: Specifications

Power Information

Power Requirements

Voltage:

95

- 250 Volts AC, 3-wire single phase, auto-ranging

Frequency:

47-63 Hz

Operating Current:

300 mA @ 120 V

Power Consumption:

40

Watts (maximum)

Fuse Rating:

1.6A, 250 Volts

Power Supply Cord

Cord type:

3 conductors, 1.0 mm2 minimum conductor size

 

(approximately 18 AWG)

Rated for:

250 Volts AC, 10 Amps

Length:

3.0 meters

Environmental Limitations

 

Temperature

 

Operating range:

5° to 50° C (41° to 122° F)

Storage range:

-40° to 66° C (-40° to 151° F)

Max temp. change/hr:

20° C (36° F)

Rapid temperature changes may affect operation. Therefore, do not operate the ETS near heating or cooling devices, large windows, or doors that open to the outdoors.

Altitude

Operating maximum:

2.4 km (8,000 ft)

Storage maximum:

9.1 km (30,000 ft)

If operating the ETS above 2.4 km (8000 ft.), decrease the operating temperature rating by 1° F for each 1000 ft.

Relative Humidity

Operating range:

10% to 90% noncondensing, 40% to 60%

 

recommended

Storage range:

10% to 90% noncondensing

ETS Installation Guide

60

Page 60
Image 60
Lantronix ETS8PS, ETS16PS, ETS32PR, ETS16PR manual Specifications, Power Information, Environmental Limitations