Lexmark 5021-0XX manual Ribbing service check, Light print occurs in right or left side of image

Models: 5021-0XX

1 385
Download 385 pages 63.9 Kb
Page 192
Image 192

5021-0XX

Ribbing service check

Light print occurs in right or left side of image.

 

Problem area

Action

 

 

 

1

Printer is not level

Table printer is sitting on is slightly

 

 

tilted.

 

 

Tilt should be less than 1/2 inch.

 

 

Confirm the printer table is large

 

 

enough and the printer is level.

 

 

 

2

Toner cartridge

Insufficient amount of toner in the

 

 

toner cartridge.

 

 

Shake the toner cartridge horizontally

 

 

several times to level the toner.

 

 

 

3

Toner cartridge

Toner in the toner cartridge is not

 

 

level and collects on one side.

 

 

Shake the toner cartridge horizontally

 

 

several times to level the toner. If

 

 

problem persists, replace toner

 

 

cartridge.

 

 

 

4

Rear cover assembly

Open rear cover assembly and close

 

 

properly.

 

 

 

5

Photodeveloper cartridge

Photodeveloper OPC belt is off rack

 

 

and becomes deformed during

 

 

operation.

 

 

Replace photodeveloper cartridge.

 

 

See “Photodeveloper cartridge

 

 

removal” on page 4-11.

 

 

Note: Photodeveloper cartridge is a

 

 

customer order supply.

 

 

 

2-114Service Manual