OPERATION

RANGER 10 / RANGER 300 D OPERATION

The table (Table 11) lists the recommended switch and control settings for the TIG Module/Ranger 10 or TIG Module/Ranger 300 D combination. Make sure all connections are tight before proceeding.

Operate the Ranger 10 or Ranger 300 D in accordance with the proper Operators Manual.

Note that for AC TIG welding, the maximum TIG welding output currents on each range setting will be approximately 50% higher that those marked on the nameplate. This is due to the special nature of the AC TIG welding arc. Do not AC TIG weld on the 200 or 250 amp range settings. The output current may exceed the rating of the Ranger 10 or Ranger 300 D.

Because your Ranger 10 / Ranger 300 D has remote control capability, refer to the diagram Figure 9 which covers the

proper use of the Tig Module Current Control, Arc Start Switches, and Amptrols.

Once the TIG Module and Ranger 10 or Ranger 300 D are properly set up, TIG welding is very easy. Position the torch in place, lower your helmet, and press the Arc Start Switch or Amptrol. The TIG Modules optional contactor will close, gas will flow for a one-half second preflow time, and the high frequency will come on. The arc should strike and welding should begin. At the end of the weld, simply release the Arc Start Switch or Amptrol, and the contactor will open, shutting off the arc. The Afterflow time will begin, cooling the torch, protecting the weld and the tungsten.

If another weld is started during the Afterflow time, there will be no preflow time delay. The contactor will close and the high frequency will come on immediately when the Arc Start Switch or Amptrol is pressed.

TABLE 11: K930-[ ] / RANGER 10 or RANGER 300 D SETTINGS

K930-[ ] SETTINGS

 

 

 

 

HF

 

 

2

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CURRENT

 

 

 

 

 

HIGH

 

 

 

CURRENT

CONTROL

 

 

POWER

FREQUENCY

AFTERFLOW

CONTROL

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

ADJUST

 

ADJUST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO SUIT,

 

TO SUIT

 

 

 

 

 

 

 

 

 

 

 

 

5 - 55 SECONDS

0-10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

START

REMOTE (WITH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- OR -

 

 

 

 

 

 

 

AN AMPTROL)

 

 

 

 

LOCAL (WITH AN

 

 

 

 

 

 

ARC START

CONTINUOUS

SWITCH)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RANGER 10 SETTINGS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IDLER

 

 

 

 

RANGE

OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

 

 

 

 

 

CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

STICK/TIG

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POLARITY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SELECT TO SUIT,

 

 

 

 

 

 

 

 

 

 

DC-

 

45 - 250

OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SELECT TO SUIT,

REMOTE

 

 

 

HIGH

 

AC

 

45-160

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TIG MODULE

 

 

 

27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 38
Image 38
Lincoln Electric IM528-B manual Ranger 10 / Ranger 300 D Operation, Ranger 10 Settings