INSTALLATION
TECHNICAL SPECIFICATIONS - TIG MODULE
INPUT - SINGLE PHASE ONLY
Standard
Voltage
115 VAC 50/60
(60VAC TO 130 VAC) 50/60 HZ.
(MIN. TO MAX.)
Duty Cycle
100%
60%
20%
Input Current
1.3 amperes
RATED CAPACITIES
Amps
200 amps AC/DC
300 amps AC/DC
400 amps AC/DC
Code
Number
10135
10203
10284
11010
Total Capacity Range
15 - 400 amps AC/DC
RECOMMENDED WELDING CABLES
|
|
|
|
|
|
|
|
|
|
| Duty Cycle |
|
| Amps |
|
| Cable sizes* (mm2) |
| |
| 100% |
|
| 200 amps AC/DC |
|
| #2 AWG | (30) |
|
| 60% |
|
| 300 amps AC/DC |
|
| #1 AWG | (35) |
|
| 20% |
|
| 400 amps AC/DC |
|
| #1/0 AWG | (50) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(*) Correct Cable size if the cable length is 150 feet (45.7 meters) or less.
PHYSICAL DIMENSIONS
Height | Width | Depth | Weight |
12.0 in. | 15.0 in. | 10.5 in. | 33 lbs |
305 mm | 381 mm | 267 mm | (15 kg) |
Insulation Class 155(F)
TIG MODULE | – 1 – |