INSTALLATION

TECHNICAL SPECIFICATIONS - TIG MODULE

INPUT - SINGLE PHASE ONLY

Standard

Voltage

115 VAC 50/60

(60VAC TO 130 VAC) 50/60 HZ.

(MIN. TO MAX.)

Duty Cycle

100%

60%

20%

Input Current

1.3 amperes

RATED CAPACITIES

Amps

200 amps AC/DC

300 amps AC/DC

400 amps AC/DC

Code

Number

10135

10203

10284

11010

Total Capacity Range

15 - 400 amps AC/DC

RECOMMENDED WELDING CABLES

 

 

 

 

 

 

 

 

 

 

 

Duty Cycle

 

 

Amps

 

 

Cable sizes* (mm2)

 

 

100%

 

 

200 amps AC/DC

 

 

#2 AWG

(30)

 

 

60%

 

 

300 amps AC/DC

 

 

#1 AWG

(35)

 

 

20%

 

 

400 amps AC/DC

 

 

#1/0 AWG

(50)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(*) Correct Cable size if the cable length is 150 feet (45.7 meters) or less.

PHYSICAL DIMENSIONS

Height

Width

Depth

Weight

12.0 in.

15.0 in.

10.5 in.

33 lbs

305 mm

381 mm

267 mm

(15 kg)

Insulation Class 155(F)

TIG MODULE

1

Page 8
Image 8
Lincoln Electric IM528-B manual Installation, Technical Specifications TIG Module