TECHNICAL SPECIFICATIONS - V205-T AC/DC™ TIG K1855-1 (Code Number 10860)

 

 

 

 

 

 

 

 

 

 

 

INPUT - SINGLE PHASE ONLY

 

 

Input Voltages / 50 /60 Hz.

 

 

 

 

 

 

 

 

 

Max. Input Current

 

 

115

 

 

 

34A at Rated Output

 

 

230

 

 

 

30A at Rated Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT

 

 

 

Duty Cycle

Output Amps

Volts at Rated Amperes

 

Input Amps

 

(115V)

35%

(Stick) 110

24.4V

 

34A

 

 

60%

 

 

90

23.6V

 

28A

 

 

100%

 

 

70

22.8V

 

20A

 

 

 

 

 

 

 

 

 

 

(115V)

40%

(TIG)

150

16V

 

34A

 

 

60%

 

 

120

14.8V

 

25A

 

 

100%

 

 

100

14V

 

20A

 

 

 

 

 

 

 

 

 

(230V)

35%

(Stick) 180

27.2V

 

30A

 

 

60%

 

 

150

26V

 

23A

 

 

100%

 

 

130

25.2V

 

19A

 

 

 

 

 

 

 

 

 

 

(230V)

40%

(TIG)

200

18V

 

30A

 

 

60%

 

 

170

16V

 

18A

 

 

100%

 

 

140

15.6V

 

15A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

Type of Output

 

 

 

 

 

 

 

 

Output Current

 

 

 

Maximum Open

 

 

 

Range

 

 

 

Circuit Voltage

 

 

 

 

 

6-200 Amps

 

 

 

 

54 Volts Max.

 

 

AC/DC

 

 

 

 

 

 

 

 

 

RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

 

TYPE S, SO ST, STO, OR EXTRA

TIME-DELAY CIRCUIT BREAKER

VOLTAGE /

 

FREQUENCY

 

HARD USAGE INPUT CORD AWG

 

OR FUSE SIZE (AMPS)

 

(HZ)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115/50/60

 

 

 

 

#12

 

 

 

30A

230/50/60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

 

 

Height

 

 

Width

 

 

Depth

 

 

Weight

 

 

15 in.

 

 

8.5 in.

 

 

19 in.

 

 

Approx. 38 lbs.

 

 

381 mm

 

 

216 mm

 

 

483 mm

 

 

17 kgs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE RANGES

 

 

 

 

OPERATING TEMPERATURE RANGE

 

 

STORAGE TEMPERATURE RANGE

 

-20°C to +40°C

 

 

 

 

 

-50°C to +85°C

 

 

 

 

 

 

 

 

 

 

 

 

 

INVERTEC® V205-T AC/DC™