Lincoln Electric SVM161-A service manual Tig Dc Tig Ac

Models: SVM161-A

1 112
Download 112 pages 28.2 Kb
Page 22
Image 22

B-6

OPERATION

B-6

 

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

3.Press and hold the TIG torch trigger when the main part of the weld is complete.

The machine will now decrease the output current at a controlled rate, or downslope time, until the Finish current is reached. Both the Downslope Time and the Finish Current are presettable. This Finish cur- rent can be maintained as long or as short as nec- essary.

4.Release the TIG torch trigger.

The output current of the machine will turn OFF and the gas valve will remain open to continue the flow of the shielding gas. The duration of this postflow time is adjusted by the Postflow parameter. This operation is shown in (4 step diagram 1).

4 STEP DIAGRAM 1

(3)(4)

Possible variations of this standard sequence are shown below.

By releasing and re-pressing the TIG torch trigger dur- ing the downslope step, the output will immediately drop to and hold at the Finish Current. Releasing the trigger will turn off the output and begin postflow. This operation shown in (4 step diagram 2)

4 STEP DIAGRAM 2

9.Welding selection button - Permits selection of the welding mode. The LED beside the symbol confirm the selection:

Stick

TIG DC

TIG AC

10.Electrode Connection (Negative) - For quick dis- connect system using Twist-MateTMcable plugs with gas pass through for TIG Torches.

11.Remote Control Connector - For the connection of a Lincoln Foot Amptrol, Hand Amptrol or Arc Start Switch. See the ACCESSORIES section for available options.

12.Electrode Connection (Positive) - For quick dis- connect system using Twist-MateTMcable plugs

13.Welding Parameter Display - LED’s show which mode or welding parameter is activated for adjust- ment.

If it is necessary to modify the welding parameters "Item 13":

-Wait four seconds after the LED’s on the panel have gone out, the welding current LED will be lit.

-Press the SETUP/Parameter push button "Item 4"; every time the push button is pressed, one of the LED’s in the diagram “Item 13” comes on (in clockwise sequence) and the value of the parameter appears on the Digital display "Item 6". Stop at the desired parameter.

-Rotate the Output/Parameter Adjust Knob"Item 5" and modify the parameter value.

-Press the SETUP/Parameter "Item 4" push button again to pass to another parameter, or wait five seconds and the Weld Current LED will come on again.

Return to Section TOC

Return to Master TOC

WELDING PARAMETER DEFAULTS AND RANGES

PARAMETER

VALUE

MIN

MAX

DEFAULT

START CURRENT

AMPS

6

MAX

15

UPSLOPE

SEC.

0

10

0.2

WELD CURRENT*

AMPS

6

MAX

100

DOWNSLOPE

SEC.

0

10

1.0

FINISH CURRENT

AMPS

6

MAX

8

POSTFLOW

SEC.

0.2

60

5.0

PULSE FREQUENCY

HZ

0.1

500

0.5

% ON TIME

%

5

95

50

BACKGROUND CURRENT

% OF WELD CURRENT

1

100

20

AC FREQUENCY

HZ

20

150

100

AC BALANCE

% EN

35

85

65

 

(EN = Electrode Negative)

 

 

 

MODE

 

 

 

DC TIG

TRIGGER

 

 

 

2 STEP

LOCAL / REMOTE

 

 

 

LOCAL

 

 

 

 

 

*Maximum Weld Current can be limited by input voltage, Welding Mode, AC TIG waveform and AC TIG frequency.

INVERTEC® V205-T AC/DC™

Page 22
Image 22
Lincoln Electric SVM161-A service manual Tig Dc Tig Ac